4.1.1 Configuring a load on a boiler
The "Select a load" menu screen appears displaying four possible loads. All loads are set to "Off"
to allow the system to be programmed to correspond to the installation’s specific wiring
connections.
To configure a load:
1. Tap
.
If the boiler has never been programmed, all loads will be set to "Off".
For example, if Load 1 is piped and wired (Load 1 = P/V1 & Therm.1) to heat a load type,
select "Load 1 - Off" button.
2. On the
Select a load
screen select a load (Load 1-4) > Select a control mode (e.g.,
Setpoint) >
OK
. To change the control mode, select the
Change...
button.
Note
Zone Of is not available as an option until you have programmed a load with
one of the other control modes.
If selecting:
Setpoint, DHW or Ext. Control, a settings screen is populated with pre-
programmed values appropriate for typical residential applications.
To change a value: Choose a setting > Using the number pad, enter a new value >
select
OK
. The temperature setting range is shown on the number pad popup. For
information on recommended settings, see
Reset Heating > Choose an emitter type (e.g., H-Mass Radiant) >
OK
. The Reset
Heating screen is populated with default settings. Ensure that these settings will
work for the intended application, and change them if necessary. For information on
recommended settings, see
. Note that an outdoor sensor
must be installed for Reset Heating.
50
Section: Settings loads
Содержание V-10
Страница 1: ...V 10 TOUCHSCREEN CONTROLLER MANUAL VX SERIES...
Страница 40: ...Intentionally left empty...
Страница 50: ...Intentionally left empty...
Страница 66: ...Intentionally left empty...
Страница 96: ...Internal wiring diagram VX series boilers Figure 21 VX series internal diagram 94 Section Appendices...
Страница 97: ...Wiring diagram Opt Out DHW Figure 22 Opt Out DHW wiring diagram 95 Wiring diagram Opt Out DHW...
Страница 98: ...Sequence of Operation VX series boilers Figure 23 VX series Sequence of Operation 96 Section Appendices...
Страница 102: ......