Referring to

Figure 4

:

B. Remove the return pipe:

i. disconnect the return pipe from the combi by loosening

the union nut (L)

ii. disconnect the return pipe from the heat exchanger by

loosening the union nut (M), and set aside the pipe.

C. Remove the supply pipe:

i. remove the retaining clip (N) from the base of the supply

pipe and combi block

Figure 4

CX Return and Supply Pipe Removal

ii. disconnect the supply pipe from the heat exchanger by loosening the union nut (O), and set aside the

pipe.

Removing the Block and Pump Assembly

1. Disconnect the pump cable:

remove and set aside the screw and top cover

unplug the ground, L and N wires

feed the wire through the side.

2. Disconnect the field piping from the fittings (R) at the bottom

of the boiler cabinet, discard the gaskets(S) and fittings (see

Figure 5

).

Figure 5

CX Combi Removal and Boiler

Fittings Connections

4. Lift the DHW Block and pump assembly out of the cabinet; remove and discard the foam seal (Q).

5. Remove the fasteners (P) that secure the pump and block assembly from the underside of the boiler

cabinet; retain the fasteners.

Reassembling the On-Demand DHW Block and Pump Assembly

1. Reassemble the replacement block and pump assembly:

a. install the combi block seal foam, ensure that the foam installed flat with no ripples