IBC BTI 119-MAX Скачать руководство пользователя страница 1

BT INDIRECT SERIES WATER HEATERS

BTI 30, BTI 40, BTI 55, BTI 65, BTI 80, BTI 80-MAX, BTI 119-MAX

FOR SINGLE WATER HEATER INSTALLATIONS

For service or repairs to the water heater, call your heating contractor. Your water heater has been 

manufactured to provide years of service. In order to insure proper service, the following information is 

provided to assist in enabling the installation, operation, and maintenance of this water heater. When the 

installation is completed, keep this manual with the water heater.
Product complies with NSF/ANSI 372 and conforms with lead content requirement for “lead-free” plumbing 

as defined by the California, Vermont, Maryland and Louisiana state laws and the U.S. Safe Drinking Water 

Act in effect as of January 4, 2014.

INST

ALLA

TION AND OPERA

TING INSTR

UCTIONS

www.ibcboiler.com

CAUTION

1. The heat transfer-medium must be water or other nontoxic fluid

having a toxicity rating or Class of 1, as listed in Clinical Toxicology 

of Commercial Products, 5th edition.

2. The pressure of the heat transfer medium must be limited to a

maximum of 30 PSIG by an approved safety or relief valve.

Содержание BTI 119-MAX

Страница 1: ...is completed keep this manual with the water heater Product complies with NSF ANSI 372 and conforms with lead content requirement for lead free plumbing as defined by the California Vermont Maryland a...

Страница 2: ...if it has been damaged or dropped 5 Installation start up and servicing of IBC Indirect Water Heaters must be done with due care and attention and should only be performed by competent qualified licen...

Страница 3: ...r 7 2 6 Temperature and Pressure Relief Valve 8 2 7 Additional Recommended Components 8 2 8 Removing the Existing Domestic Water Heating System 8 2 9 Water Quality 9 3 0 PIPING 10 3 1 Domestic Water P...

Страница 4: ...event scalding injuries Do not rely on the pressure and temperature gauges to determine the temperature and pressure of the water heater This water heater contains components that become very hot when...

Страница 5: ...0 BTI 80 MAX 79 9 70 0 23 8 1 1 1 2 3 4 1 141 1 BTI 119 MAX 114 6 65 75 28 9 1 1 2 1 1 2 3 4 1 177 5 Table 1 Dimensions and Capacities Maximum Allowable Working Pressure 150 psi Hydrostatically teste...

Страница 6: ...capacity the water heating output will be reduced 3 Circulator sizing Refer to Table 2 for the flow through the water heater coil and the pressure drop at minimum flow Calculate the pressure drop acr...

Страница 7: ...in an area where water leakage from the tank or connections will not result in damage to areas adjacent to the water heater or to lower floors of the structure When such a location can not be avoided...

Страница 8: ...nkless Heaters Disconnect the domestic piping Do not plug the cold water or the hot water fittings in the internal tankless coil Leave the coil in the boiler with the cold and hot water fittings open...

Страница 9: ...ater Quality Improper water quality will reduce the expected life of the water heater Hard water sediment high or low pH and high levels of chlorides in the domestic water should be avoided Sediment a...

Страница 10: ...ns in the faucets Check the system for leaks Repair as required 3 2 Boiler Water Piping See Figures in Section 8 0 1 Determine where the boiler the space heating and the water heater connections shoul...

Страница 11: ...ter connection labeled BOILER SUPPLY should be piped to the boiler supply piping after the air purger and grouped with the other zone supplies The use of a shut off valve is recommended for future ser...

Страница 12: ...he temperature of the sensed environment and compare with the value derived from the measurement of the resistance obtained by connecting a good quality test meter capable of measuring up to 5 000 k 5...

Страница 13: ...ube sensing bulb so that it is at a right angle to the back of the control Loosen the mounting screw and carefully insert the sensing bulb into the well until the control mounts to the well head Tight...

Страница 14: ...will have to be used and the thermostat must go through the cycle of heating cold water and satisfying at the new lower temperature Additional temperature checks should follow the completion of a heat...

Страница 15: ...m chemical cleaning may be required Proceed as follows 6 1 Chemical Cleaning of the Heating Coil 1 To avoid water damage shut off the cold water supply to the water heater 2 Make a note of the DHW tem...

Страница 16: ...ue Water Heater Circulator does not operate Follow steps for Boiler does not operate Ensure the pump relay is closed and suppling power to the pump Ensure the zone valve is open and the end switch is...

Страница 17: ...r and its fan on a call for heat This may result in operation of these components when other loads are running at a higher priority resulting in cold air blowing or robbing heat from another load Some...

Страница 18: ...equired to ensure adequate flow under low load conditions BT Series Indirect Hot Water Tank 120VAC HOT COM Heating circ AC in Primary Pump Boiler Pump yellow L N L N white white black DHW circ Factory...

Страница 19: ...19 INSTALLATION AND OPERATION INSTRUCTIONS BT INDIRECT SERIES WATER HEATERS Figure 6 Suggested Domestic Water Piping...

Страница 20: ...INSTALLATION AND OPERATION INSTRUCTIONS 20 BT INDIRECT SERIES WATER HEATERS SERVICE RECORD DATE LICENSED CONTRACTOR DESCRIPTION OF WORK DONE...

Страница 21: ...21 INSTALLATION AND OPERATION INSTRUCTIONS BT INDIRECT SERIES WATER HEATERS NOTES...

Страница 22: ...INSTALLATION AND OPERATION INSTRUCTIONS 22 BT INDIRECT SERIES WATER HEATERS NOTES...

Страница 23: ...R1 JULY 2015 Initial release R2 SEPTEMBER 2015 Certified release R3 JUNE 2016 Updates to dimensions and capacities table updates to ratings table R4 JUNE 2017 Updates to drawings for side connections...

Страница 24: ...IBC Technologies Inc 8015 North Fraser Way Burnaby BC Canada V5J 5M8 Tel 604 877 0277 Fax 604 877 0295 www ibcboiler com 120 221A1 R4 June 2017 IBC Technologies Inc 2017...

Отзывы: