Measure the thickness of the door. The
BioBolt often requires the tailpiece that
turns the deadbolt be the trimmed to the
appropriate length for the thickness of the
door.
Adjusting the Tailpiece for the Proper Door Thickness
Identify the amount of the tailpiece that will
need to be trimmed based on the following:
!
2 1/4” - 2 ½”
= Use Full Tailpiece (A)
!
1 3/4” - 2 1/8” = Trim 2 Notches (B)
!
1 3/8” - 1 5/8” = Trim 4 Notches (C)
A
C
B
With two pairs of plyers, use one pair (A) to
hold the tailpiece just below necessary
notch (B).
Using the second pair of plyers (C), grab
the upper portion of the tailpiece and slightly
bend the top portion of the tailpiece being
careful NOT TO MOVE THE BOTTOM PAIR
OF PLYERS (A)!!
Continue to slightly bend the tailpiece
back
and forth
until the top potion of the tailpiece
breaks off at the desired notch (B).
A
B
C
2
Before proceeding with final installation:
Fit the front and back lock bodies together on
the door to ensure the tailpiece does not hinder
the flush placement of both bodies to the door.
If there is ANY gap due to the length of the
tailpiece (A), remove one more notch from the
tailpiece and repeat this step until the front and
back lock bodies join without any gap.
WARNING: Forcing the front and back lock
bodies together may damage the internal
motor drive VOIDING THE WARRANTY!!
A
DO NOT FORCE FRONT
AND BACK LOCK
BODIES TOGETHER!
BioBolt Biometric Deadbolt
Intelligent Biometric Controls
Installation Manual