Place the Rubber Gaskets (A) on the rear 
potions of the front and back lock bodies.  
A small lip should surround the lock bodies.  
The potion of the gasket that makes 
contact with the door should be smooth 
and flat.

Installing the BioBolt on a US Standard Preparation Door

With the gasket attached, place the front lock 
body (the side with the scanner) through the 
door hole.  Be sure to align the tailpiece (A) 
vertically through the deadbolt cross slot (E).  
Only a small portion, if any, of the tailpiece 
should extend through the door width (A).  

Also, be sure to pass the Control Cable (B) 
through the hole.

With the front lock body held against the door 
with the tailpiece aligned vertically (A), verify 
that the Motor Drive Coupler (D) is also 
aligned vertically.

Now, connect the Control Cable (B) to the 
corresponding Control Connector (C) on the 
back lock body. 

A

B

A

A

B

C

E

D

3

Align the front and back lock bodies so they 
are straight on the door.  Insert the two bolts 
in the corresponding holes and try to thread 
them into the front lock body.  

Locate the Bolt Direction Switch (A) just under 
the batteries.  Make sure the Bolt Direction 
Switch corresponds with the direction that the 
bolt extends (B).  In the example to the right, 
the bolt extends out of the left side of the door.  
Therefore the switch should be moved to the 
left as shown by the diagram (C).

A

C

B

BioBolt Biometric Deadbolt

Intelligent Biometric Controls

Installation Manual