Page 11
Peak flow not recommended for extended periods of time.
Brine Tank:
1000 litre L.D.P.E. moulded construction
complete with lid.
Brine Valve:
Plastic construction.
Operation Pressure:
210 - 600 kPa
Temperature:
5 - 50 degrees C
Electrical:
240v 50Hz 3w maximum
WARNING:
A pressure reduction valve should be installed in areas of high water
pressure (above 690 kPa).
A water hammer arrester should be installed if water hammer prevails.
FAILURE TO OBSERVE WARNINGS WILL VOID WARRANTY
Table 3
Model
No.
Capacity
&
Salt Dosage
Service Flow
Rate
Pipe Size
Resin
Volume
Approx.
Shipping
Weight
Space
Requirements
Minimum
Maximum
Peak
Flow
Continuous
Flow
Inlet
Outlet
Drain
Litres
wt/kg
W x D x H
grams/kg
grams/kg
l/m
l/m
mm
mm
metres
AS30500
17500/32
35000/120
350
265
50
40
500
915
1.8x1.2x2.6
PERFORMANCE DATA
MEDIA LOADING
Model
Underbed Gravel No.6
Resin Content
Brine Tank Gravel No.4
kg
litres
kg
AS30500
120
500
120