Maintenance work 

8.1 

Basic procedure 

If you carry out any maintenance work at the device, always proceed in the following 

way: 

1. 

Remove all mobile data carriers (DVD, memory cards and so on). 

2. 

Shut down the device. 

3. 

Switch off the device. 

4. 

Unplug the mains cable from the socket. 

5. 

Remove the housing cover. 

6. 

Carry out the maintenance work. 

7. 

Attach the housing cover again. 

8. 

Put the device into operation again. 

8.2 

Cleaning or replacing the dust filter 

Depending on the installation site it is necessary to clean or replace the dust filter in both 

grids. The dust filter should be replaced every 6 months. 

1. 

Loosen the fastening screw which is used to fix the grid and open the grid.  

     

2. 

Take the dust filter out of the grid. 

3. 

Clean the dust filter or insert a new one (iba filter mat: Order number 43.000360). 

4. 

Close the grid again and fasten the screw. 

 
 
 
 

Содержание ibaRackline

Страница 1: ...ibaRackline iba Industrial Computer Manual Issue 1 16...

Страница 2: ...red trademark of the Microsoft Corporation Other product and company names mentioned in this manual can be labels or registered trademarks of the corresponding owners Certification The device is certi...

Страница 3: ...16 6 1 Safety instructions 16 6 2 lnstallation 16 6 3 Connection and first switching on 16 7 Installation of measuring or additional boards 17 7 1 Safety instructions and notes 17 7 2 Basic procedure...

Страница 4: ...ge 37 9 2 3 Enter the product key 37 9 2 4 Partitioning 37 9 2 5 Completing installation 39 9 3 Windows Updates 40 9 4 Antivirus Software 40 9 5 Installing iba software 40 10 Device dimensions 41 11 T...

Страница 5: ...assessing safety and recognizing possible consequences and risks on the basis of his her specialist train ing knowledge and experience and knowledge of the standard regulations 1 2 Designations The f...

Страница 6: ...the system or machine to be controlled there is a risk of death or severe injury The non observance of this safety information may result in a potential risk of death or severe injury The non observan...

Страница 7: ...tation contains Manual pdf Subcontractors documentation pdf Windows 10 Enterprise Long Term Servicing Version or Windows Server Version Recovery DVD for the ordered Windows version and all associated...

Страница 8: ...The net volume corresponds to the volume of approx 6 hard disks with simultane ous high performance and system stability against failure Server system with Windows Server 2016 or later ibaRackline wi...

Страница 9: ...socket equipped with an earthing contact and wait for several minutes until the com ponents have cooled down Thus you will avoid injuries due to the electric shock or burns Connect the device to one...

Страница 10: ...cal drive with integrated writing function Plug in slots for hard disks Note On delivery of the device the iba software license key is in the documentation or on client s request plugged in in the dev...

Страница 11: ...yboard mouse network etc Hard disk controller Slots X3 to X7 PCIe Slot X8 PCI 5 2 2 Version with redundant Power Supply e g RAID system RAID systems are equipped with a redundant power supply unit 2x...

Страница 12: ...Express slots 1x PCI slot Hard disk controller Slots for iba cards for rackline slot or additional fan as option Power supply unit for RAID systems redundant Drive frame Fan 12 cm mounting angle for...

Страница 13: ...ed each with a bicolored LED on the cards LED Status Description TEMP green red Temperature OK Overtemperature POWER green red Power supply OK Power supply error Redundant power supply error in one of...

Страница 14: ...ides an output 6 pin connector which can be used to indicate errors Both error types are indicated separately These are the switch positions Switch state switch state Power OK temperature OK Power off...

Страница 15: ...nstallation slots for cards with rackline slots X20 X26 ibaOut Temp or ibaOut State is installed in slot X20 ibaFOB 4o D rackline slot is installed starting with X25 and connected to X7 down wards iba...

Страница 16: ...stall the device into a 19 cabinet with rotating rack consider the depth of the device Observe the minimum bending radii of the cables 1 Place the device from the front onto the 19 rack line 2 Fasten...

Страница 17: ...Pay attention to sharp edges in the housing Electrostatic discharge Touch the components only in electrostatically discharged state Note If you upgrade the device observe the instructions in the subco...

Страница 18: ...Manual ibaRackline 18 Issue 1 16 7 3 Opening the device 1 Turn the screws located on the upper side of the cover a quarter of a turn counter clockwise 2 Lift the housing cover...

Страница 19: ...on the example of ibaOut Temp ibaOut Temp Order no 11 110001 ibaOut State Order no 11 110002 After having opened the housing cover proceed as follows 1 ibaOut Temp can be installed in one of the slots...

Страница 20: ...ch the components only in electrostatically discharged state Hold the card cautiously at the edges and at the slot bracket 4 Insert the card in the respective slot The bar at the bottom is used to fix...

Страница 21: ...card This connec tion is not necessary when a standard power supply unit is used 2 Power supply connection Use the cable included in delivery Connect the con nector of the power supply cable from the...

Страница 22: ...eded it is possible to install one or two additional fans in the slots X21 to X26 Each fan requires the space of 3 slots Fan 60 x 60 x 25 mm complete module Order no 43 000365 After having opened the...

Страница 23: ...6 23 2 Loosen the screws in the openings above the slots 3 Insert the fan module on the inner side on the rear cover for this purpose push the bent slot bracket onto the rear cover Fasten the fan with...

Страница 24: ...Issue 1 16 4 Insert the plug of the fan power supply cable into the appropriate plugs on the moth erboard see picture below 5 The guide pins on the plug ensure a proper position of the connection 6 Cl...

Страница 25: ...Carry out the maintenance work 7 Attach the housing cover again 8 Put the device into operation again 8 2 Cleaning or replacing the dust filter Depending on the installation site it is necessary to c...

Страница 26: ...ean the fan or insert a new one 5 Connect the cables of the fan and the cables of the computer with the cable con nector 6 Insert the fan again 7 Fasten the fan with the 4 srews at the housing 8 4 Rep...

Страница 27: ...supply unit at the housing 2 Loosen 2 screws each on the left and the right side which are used to fix the bar 1 and remove the bar 3 Disconnect all cable connections to the mainboard and the drives 4...

Страница 28: ...ng screw 1 Loosen the fastening screw which is used to secure the power supply slide in module at the rack 2 Pull out the power supply slide in module Replace the power supply slide in module with the...

Страница 29: ...t and the right side which are used to fix the bar 1 and remove the bar 5 Disconnect all cable connections to the mainboard and the drives 6 Remove the power supply unit 2 from the housing by pulling...

Страница 30: ...Manual ibaRackline 30 Issue 1 16 8 In order to install a new power supply unit proceed in reversed order...

Страница 31: ...r Note The program maxView Storage Manager is included on the DVD Drivers and Manu als maxView Storage Manager is a web application which requires a web browser e g Internet Explorer Note The program...

Страница 32: ...indicated 4 Mark the hard disk which is available Device 1 in the example above and click on the Locate icon in the Physical device section The available hard disk blinks in the drive frame 5 Replace...

Страница 33: ...the hard disk has not been registered in the system 7 Mark the new hard disk Device 2 in the example above and click on the Initialize icon in the Physical Device section 8 Then click on the Spare Ma...

Страница 34: ...Manual ibaRackline 34 Issue 1 16 10 Confirm the following overview with Finish 11 The following message appears when the operation was successful Otherwise an error message appears...

Страница 35: ...ibaRackline Manual Issue 1 16 35 12 The progress of the rebuild process is displayed under Tasks 13 As soon as the hard disk has been successfully registered in the system the pro gram can be closed...

Страница 36: ...f the device components e g motherboard If you modify the device components it may not be possible to install it with the Recov ery DVD 9 2 Installing Windows from the recovery medium Important note T...

Страница 37: ...ed subsequently 9 2 3 Enter the product key only with Windows Server 2016 or higher With Windows Server a product key must be entered subsequently This is printed on the back of the housing Note When...

Страница 38: ...it completely as system drive Click Next and continue with chapter 9 2 5 Completing installation Possibility 2 Partitioning the new drive You use a new drive and want to set up partitions 1 Click Driv...

Страница 39: ...500 MB in size 2 Click Format 3 Confirm with OK 4 Mark the primary partition normally the smaller one 5 Click Format 6 Confirm with OK 7 Click Next and continue with chapter 9 2 5 Completing installat...

Страница 40: ...s according to the update policies in your company Consult your IT department if necessary 9 4 Antivirus Software There is no antivirus software installed on iba systems in delivery state Please insta...

Страница 41: ...ibaRackline Manual Issue 1 16 41 10 Device dimensions Dimensions given in mm...

Страница 42: ...00 W ibaRackline RAID 1 6 AC 100 V to 240 V 8 A 4 A 47 Hz to 63 Hz Power output ibaRackline RAID 1 6 1 x redundant 500 W Mechanical data Installation height HU Height Unit 4 HU Dimensions Height x Wid...

Страница 43: ...0 Mbps 1000 Mbps HD audio on board Realtek ALC892 Main memory 32 GB DDR4 PCI Express x16 SAS controller Microsemi Adaptec SmartRAID 3102 8i PCI Express free 5x for iba measuring cards PCI free 1x M 2...

Страница 44: ...0420 HD 600GB to 1800GB Upgrade SAS 43 000421 HD 600GB to 2400GB Upgrade SAS 43 000422 Upgrade ibaRackline PC CAM with NVME SSD for OS installation 43 001002 Accessories HD 600 GB SAS 43 000326 HD 120...

Страница 45: ...product Contact Headquarters iba AG Koenigswarterstrasse 44 D 90762 Fuerth Germany Phone 49 911 97282 0 Fax 49 911 97282 33 E mail iba iba ag com Mailing address iba AG Postbox 1828 D 90708 Fuerth Ger...