background image

 

Manual 

ibaBM-DDCS 

 

26

 

Issue 1.11 

 

 

ibaPDA only supports the acquisition of analog parameter values in 32-bit IEEE-Float 

format and digital parameter values.  

 

Important note 

Analog parameters in other formats, e. g. DINT, are misrepresented in ibaPDA. 

 
When there is only one drive, ibaBM-DDCS can be connected directly to the CH3 port  

(service channel) of the drive. When there are several drives, the communication can be 

established using a NDBU-95 in star or ring topology. 

8.4.2 

Star topology 

Several drives can be accessed via one or more NDBU-95 devices (DDCS branching 

unit). 8 drives can be connected to each NDBU-95. Up to 16 NDBU-95 devices can be 

cascaded. 
ibaBM-DDCS is connected to the MSTR port of the NDBU-95 with a bidirectional FO 

cable.  

 

Important note 

When acquiring parameters in a star topology, ensure that the connected drives are set 

to “Star” mode.  
In DriveWindow, the parameter “CH3 HW CONNECTION” in the parameter set “DDCS 

Control” of each drive has to be checked and set to “STAR”.

4

 

 

 

                                                      

4

 See important note and footnote 1 on page 19 

Содержание ibaBM-DDCS

Страница 1: ...ibaBM DDCS Manual Issue 1 11 1 ibaBM DDCS Bus monitor for the DDCS drive bus from ABB Manual Issue 1 11...

Страница 2: ...red trademark of the Microsoft Corporation Other product and company names mentioned in this manual can be brands or trade names of the corresponding owners Certification The device is certified accor...

Страница 3: ...er side 12 7 5 Device layout 13 7 5 1 Operating status display status LEDs 1 13 7 5 2 Status LEDs data set query 2 14 7 5 3 Status LEDs parameter query 3 14 7 5 4 24 V power supply 4 14 7 5 5 X30 Rx 5...

Страница 4: ...uration in the I O Manager 32 9 1 1 ibaBM DDCS General tab 33 9 1 2 ibaBM DDCS Diagnostics tab 35 9 1 3 Module type Data set 35 9 1 4 Module type Parameter 38 9 1 5 Module type Diagnose 40 9 1 6 Modul...

Страница 5: ...of assessing safety and recognizing possible consequences and risks on the basis of his her specialist training knowledge and experience and knowledge of the standard regulations 1 2 Notation In this...

Страница 6: ...ss and the system or machine to be controlled there is a risk of death or severe injury The non observance of this safety information may result in a potential risk of death or severe injury The non o...

Страница 7: ...ibaBM DDCS is handled by the bidirectional iba fiber optic protocol 32Mbit Flex which requires an I O card of the ibaFOB D generation e g ibaFOB 2io D The sampling rate can be up to 40 kHz whereby up...

Страница 8: ...ibaBM DDCS 8 Issue 1 11 3 Scope of delivery The scope of delivery includes ibaBM DDCS device Manual 2 pin plug for power supply See www iba ag com for other accessories not included in the scope of de...

Страница 9: ...ch cable duplex for connecting ibaBM DDCS and ibaPDA computer 4 2 Software ibaPDA V6 26 or higher for capturing recording and displaying the measurement data and for configuring the device ibaAnalyzer...

Страница 10: ...perating voltage range Stay within the operating voltage range of DC 24 V 10 Do not open the device There are no components requiring maintenance in the device Opening the device voids your warranty N...

Страница 11: ...Connect the power supply Observe the correct polarity 4 Connect the other cables 6 2 Disassembly 1 Disconnect the power supply 2 Disconnect all cables 3 Close the open fiber optic inputs and outputs w...

Страница 12: ...e signals which are exchanged between controller and drive data set channel Active querying of additional measurements and parameters from the drives parameter channel Loopthrough of configuration and...

Страница 13: ...itch S1 12 FO output X10 TX 13 FO input X11 RX Figure 1 Device layout 7 5 1 Operating status display status LEDs 1 LED Status Description Run green red red on green blinking off Device starting if the...

Страница 14: ...f Connection for DriveWindow released Connection for ibaBM DDCS released Link yellow blinking Blinks when a message is received steadily lit when several messages are being received Resp white on blin...

Страница 15: ...topology The devices are addressed via the rotary switch S1 Device numbers in the cascade Rotary switch position Not allowed 0 1st Device 1 2nd Device 2 14th Device E 15th Device F 7 5 9 Fiber optic...

Страница 16: ...cted to the NDBU 95 Alternative connection ibaBM DDCS is integrated in the connection between NDBU 95 and ABB control 2 Querying of other values from the drives in the parameter data channel CH3 conne...

Страница 17: ...ard in a fiber optic ring topology e g ibaPADU S IT ibaBM eCAT The rotary switch S1 has to be set to a unique device number at each device Keep in mind that the total data rate in the fiber optic ring...

Страница 18: ...de a given measurement or status value with ABB The ABB control sends even data set numbers 2n to the drives which answer with the next odd data set number 2n 1 ABB control Drive Query response Data s...

Страница 19: ...ed via a unidirectional FO cable to that NDBU 95 which is next to the controller This NDBU 95 must be operated in REGEN mode then the device can read all telegrams including the response telegrams sen...

Страница 20: ...d and saved in the parameter APPLICATION MACRO of the set START UP DATA z B Par 99 03 Settings at the branching unit NDBU 95 Address settings S1 Address range 76 124 Default setting 01111100 0x7C S1 O...

Страница 21: ...es DDCS branching unit are used to distribute the DDCS telegrams 8 drives can be connected to each NDBU 95 Up to 16 NDBU 95 devices can be cascaded The device ibaBM DDCS is coupled into the FO connect...

Страница 22: ...de Important note When acquiring data sets in a star topology ensure that the connected drives are set to Star topology In DriveWindow the parameter CH0 HW CONNECTION in the parameter set DDCS Control...

Страница 23: ...s The telegrams are sent from one drive CH0 to the next one via a FO ring Every drive CH0 takes the data which are addressed to it from the data stream and sends the reply data to the next drive The l...

Страница 24: ...data sets in a ring topology ensure that the connected drives are set to Ring mode In DriveWindow the parameter CH0 HW CONNECTION in the parameter set DDCS Control of each drive has to be checked and...

Страница 25: ...via handshake request response by the drive the access cycle depends directly on the number of values which are requested A standard value is approx 2 ms per analog value and approx 2 ms per 16 digit...

Страница 26: ...lished using a NDBU 95 in star or ring topology 8 4 2 Star topology Several drives can be accessed via one or more NDBU 95 devices DDCS branching unit 8 drives can be connected to each NDBU 95 Up to 1...

Страница 27: ...ir POF Figure 10 ibaBM DDCS parameter in STAR topology Settings at the branching unit NDBU 95 Address settings S1 Address range 76 124 01001100 01111100 0x4C 0x7C Note When NDBU 95 units are cascaded...

Страница 28: ...y A ring topology may often be found in older plants The telegrams are sent from one drive to the next one via a FO ring Every drive takes the data which are addressed to it from the data stream and s...

Страница 29: ...third fiber optic connection for connecting an external computer with DriveWindow software The communication between the DriveWindow computer and the drives is looped through ibaBM DDCS there is no ac...

Страница 30: ...tion status you can see the current number of bytes that are transferred Access via data set The data cycle depends on the limitation on the FO side which is described above Access via parameter As ev...

Страница 31: ...lues which are set to Fast and 6 slow values The 2 fast values and 1 slow value are sent with each cycle in total 3 values Hence one cycle takes 6 ms Each slow value is captured in every 6th cycle tha...

Страница 32: ...the I O Manager Click on the link with the right mouse button which opens a submenu Select Add module Another submenu with all available devices will be displayed Select ibaBM DDCS from this list ibaB...

Страница 33: ...there is also the module type Data set telegram counters available Figure 14 Adding modules 9 1 1 ibaBM DDCS General tab Here you can see the standard settings for the device Figure 15 ibaBM DDCS Gen...

Страница 34: ...ction If this is successful the measurement will be restarted FALSE the measurement is not started if ibaPDA cannot establish a connection to the device DDCS Data set speed CH0 You can select the spee...

Страница 35: ...pdate file bmddcs_vxxx iba in the browser window and start the update with OK The procedure takes several minutes and must not be interrupted Reset to factory defaults Please note that configurations...

Страница 36: ...ill be overwritten by the default value The default value can be preset in the Analog and Digital tabs False In the event of a timeout the last transmitted value will remain Module Layout No analog si...

Страница 37: ...umber slave data set number and index are entered automatically Figure 19 Overview of the data set signals Complete control words status words and fault words can be captured as analog value and itemi...

Страница 38: ...odified Locked True No changes possible Only authorized users can unlock modules False Any user can make changes Enabled True Data acquisition is enabled for this module False Data acquisition is not...

Страница 39: ...o select the parameter signals click on Browse in the bottom field The parameter browser will open and the nodes drives will be displayed Only the active nodes drives will be displayed here In the tre...

Страница 40: ...be applied to the device and the measurement will automatically start Note Make sure that a signal is not requested twice In case of duplicate signals ibaPDA displays the an error message when startin...

Страница 41: ...ase used for this module Use name as prefix If TRUE is selected the module name is placed in front of the signal name as prefix The diagnose data is pre defined in the Analog and Digital tab The diagn...

Страница 42: ...dules could be imported in the I O Manager Module 290 diagnostic counter for data set telegrams drive 1 16 Module 291 diagnostic counter for data set telegrams drive 17 32 Module 299 general diagnosti...

Страница 43: ...drives 1 to 127 are pre defined in the Analog tab The telegram counters can be visualized and saved like measured values Figure 27 Data set telegram counters Analog tab 9 1 7 Display of the measured v...

Страница 44: ...CS 44 Issue 1 11 Figure 29 Actual values of the digital signals All selected signals will be displayed in the ibaPDA signal tree You can capture and record the measurements as usual Figure 30 Measurem...

Страница 45: ...er 1 e g connection to ibaPDA ibaNet protocol 32Mbit Flex Data transmission rate 32 Mbit s Sampling rate Up to 40 kHz freely adjustable Connection type 2 ST connector 62 5 m 125 m cable length up to 2...

Страница 46: ...formation Unique Identifier 13 120710 ibaBM DDCS Responsible Party U S Contact Information iba America LLC 370 Winkler Drive Suite C Alpharetta Georgia 30004 770 886 2318 102 www iba america com FCC C...

Страница 47: ...ibaBM DDCS Manual Issue 1 11 47 10 2 Dimension sheet Dimensions in mm Figure 31 Dimension sheet ibaBM DDCS Dimensions in mm Figure 32 Dimension sheet ibaBM DDCS with cables...

Страница 48: ...product Contact Headquarters iba AG Koenigswarterstrasse 44 D 90762 Fuerth Germany Phone 49 911 97282 0 Fax 49 911 97282 33 E mail iba iba ag com Mailing address iba AG Postbox 1828 D 90708 Fuerth Ger...