- 11 -
7.3. Parameter list
NO.
Content
Adjust range
Step length
P0
Water Pump Running Way
0: Continuous
1: Water temp control
2: Time/water temp control
1
P1
Time Setting
(Only available when the
water pump running way
is set to “2”)
10 ~ 120 min
5 min
P2
Compressor Continuously
Running Time
betweenDefrosting Mode
30 ~ 90min
1min
P3
Defrosting EntryTemp
-17~0°C
1°C
P4
MaximumDefrosting
Running Time
1 ~ 12min
1min
P5
Defrosting ExitTemp
8~30°C
1°C
7.4.
Running status checking
Press
for 5 seconds, enter into “Running status checking”, and the
screen alternately shows status point “C0”and its corresponding value.
Check all status points and their corresponding value through
or
, Press
to quit “running status checking” mode.
Running status checking list
Symbol
Content
Unit
C0
Inlet water temp.
°C
C1
Outlet water temp.
°C
C2
Ambient temp.
°C
C3
Exhaust temp.
°C
C4
Outer coil pipe temp. (Evaporator)
°C
C5
Gas return temp.
°C
C6
Inner coil pipe temp. (Titanium heat
exchanger)
°C
C9
Cooling plate temp.
°C
C10
Electronic expansion valve opening
P
C11
DC fan speed
(r/min)