- 6 -
2)
In order to guarantee the heating efficiency, the water pipe length
should be ≤10m between the pool and the heat pump.
A.
Installation
1)
The swimming pool heater should be installed in a location with good
ventilation;
2)
The frame must be fixed by bolts (M10) to concrete foundation or
brackets. The concrete foundation must be solid and fastened; the
bracket must be strong and antirust treated;
3)
Don’t stack substances that will block air flow near inlet or outlet area,
and no barrier within 0.5m behind the main heater, or the efficiency of
the heater will be reduced or even haulted;
4)
The heater needs an appended pump (Supplied by the user). The
recommended pump specification-flux: refer to Technical Parameter,
Max. lift ≥10m;
5)
When the heater is running, there will be condensation water discharged
from the bottom. Please hold the drainage nozzle (accessory) into the
hole and attach it well, then connect a pipe to drain the condensation
water out.
B.
Wiring
1)
Connect to appropriate power supply; the voltage should comply with
the rated voltage of the products.
2)
Heater must be grounded.
3)
Wiring must be handled by a professional technician according to the
circuit diagram.
4)
Set leakage protector according to the local code for wiring (leakage
operating current ≤ 30mA).
5)
The layout of power cable and signal cable should be orderly and not
interfere with each other.
6)
The appliance shall be installed in accordance with national wiring
regulations.
C.
Switch on after finishing all wiring construction and re-checking.
Pay attention to the following points:
The heat pump must be installed OUTSIDE in a well-ventilated area to
avoid air recirculation, or in a place with adequate room for both
installation and maintenance. Please refer to the following illustration: