ibaPADU-16-M
Right-click the link of the FOB-D or FOB-S card to which the ibaPADU-16-M is con-
nected and select “Add module” - "Padu 16-M" from the submenu
or click to the blue text link "Click to add module…" and select the Padu 16-M inter-
face from the displayed list.
Result:
When the device is connected correctly with two bidirectional fibre optic links, two
modules of the Padu 16-M (A) and (B) are defined on the connected links. You see the
communication status OK in the Info tab of the connected links.
Note
When using ibaPADU-16-M together with other interfaces you must connect the
ibaPADU-16-M to the links beginning with the 1
st
link of the FOB card that is config-
ured as "Interrupt Master".
Note
All links configured for M mode must be connected correctly. Otherwise the acquisition
won't start.