2.14 Acceleration Setup
Acceleration setup controls the acceleration of each axis. The value entered in this setting
is a robot parameter and its exact relation to the robot’s acceleration is beyond the scope
of this manual.
In general, the value of the acceleration parameter is inversely related to the robot’s
acceleration. A small value will result in a high acceleration and vice versa.
Very small values can make the motors slip and can cause the driver cards to over heat.
The default value is 25 for all the axes and values lower than 15 are not recommended.
2.15 Pause Status
Pause
Status sets the position to which the tip will move after pressing the Start button.
There are two options:
•
Home position: The tip will move to the home position.
•
Stand: The tip will stay at the position where the Start button was pressed.
2.16 Dispense Off Distance
Usually the material continues flowing after the dispenser is off, due to pressure built in
the system.
Dispense off Distance
will automatically turn off the dispenser a user defined
distance before the end of a line, preventing excess of material to be deposited at the end
of the line.
The value will be used for all lines from the current memory address forward until another
Dispense Off Distance instruction is found.
Dispenser Turns Off here
Tip continues moving to end of line
Dispenser Off distance