![I&J Fisnar I&J7000C Скачать руководство пользователя страница 34](http://html.mh-extra.com/html/iandj-fisnar/iandj7000c/iandj7000c_operating-manual_601972034.webp)
I&J7000C Series Operating Manual
Section 4: Programming Example
Part # 561978C
Rev. F Dec. 06
- Page
33
-
© 2006 I&J Fisnar Inc.
Instruction Display
Shows
1
Follow the instructions found in section
SECTION
2:3. Setup
to setup the robot.
2
Select program
1 0
using the program number
selection switches on the main unit control panel.
Turn the power on.
[MACHINE HOME]
+------------+
| START/HOME |
+------------+
3
Press the
START
button. The robot will move to
the home position.
ADDR:1 PROG:10
EMPTY
X:0.00 Y:0.00 Z:0.00
4
Press the
Setup
key, then
1
to select Line Speed
to register a line speed of 40 mm/second at
memory address number 1.
Line Speed Setup
----------------
Speed:
unit: mm/sec
5
The robot is now waiting for the speed to be
registered. Press
4 0
then
ENTER
to register a
speed of 40 mm / second.
ADDR:2 PROG:10
EMPTY
6
The display shows we are at memory address 2
and that it is empty.
Jog the dispense tip to the first location in the
diagram above (1:Line Start).
To jog the X and Y axes, press the arrow keys
(
←
←
←
←→
→
→
→↑↑↑↑↓↓↓↓
)
.
To jog the Z axis, press the
Z
↑↑↑↑
and
Z
↓↓↓↓
keys.
Press and hold the
FAST
key to jog fast. See
SECTION 3:
SECTION
3:2.4 Jogging
for more
information.
7
Once the tip is at the correct X, Y, Z location for
the first point (
1:Line Start
), press the
ENTER
key, then
2
to register the location as a Line Start
point.
ADDR:3 PROG:10
EMPTY