I&J7000C Series Operating Manual
Section 4: Programming Example
Part # 561978C
Rev. F Dec. 06
- Page
35
-
© 2006 I&J Fisnar Inc.
Instruction Display
Shows
18
Jog the tip to the location of third dispense point
(
10: Dispense Point
). When the location is
correct, press the
ENTER
key, then
1
to register
the location as a Dispense Point.
ADDR:13 PROG:10
EMPTY
19
The program is now complete.
Press
ENTER
, then
7
to register address 13 as
the END of the program.
ADDR:14 PROG:10
EMPTY
20
To run the program, press the
RUN
key..
2
Good Programming Practices
It is recommended to register the setup commands at the beginning of every program. The
following setup commands are the most used:
•
Dispense End Setup
•
Point Dispense Setup
•
Line Dispense Setup
•
Line
Speed
•
Z
Clearance
•
Retract
•
Adjust
Origin
For a complete list and description of all the different setup commands, refer to SECTION
5: Point Type & Function Reference
3
Editing a Program
You can move through the instructions in an existing program by using the following keys:
Key Function
+1
Moves forward (1) memory address
-1
Moves backward (1) memory address
FIRST
Moves to the first memory address in the program
END
Moves to the last programmed memory address in the program
+10
Jumps forward (10) memory addresses
-10
Jumps backward (10) memory addresses
MOVE
Moves the tip to the XYZ point location of the selected point
JUMP
Jump to display to specified memory address