16-11. Driver Power Recovery Request (RPwr) and Action Pause Release
Request (Ract)
(1) Driver Power Recovery Request
①
How to execute Driver Power Recovery Request
Execute Driver Power Recovery Request by any of the following:
▪
Set 1 in I/O parameter No.44 (Input Select Function 014 = Driver Power Cut-off Release
Input) and ON edge input on Input port No.14.
▪
From the software menu, execute Controller
→
Driver Power Recovery Request.
▪
From the mode selection screen of the teaching pendant, select Ctl (Controller operation)
→
RPwr (Driver Power Recovery Request) and execute.
②
Case which requires executing Driver Power Recovery Request
Only the following case requires executing Driver Power Recovery Request:
▪
When you set 1 in I/O parameter No.44, Driver Power Cut-off cause occurs
→
Recover
after the main cause of cut-off is solved.
(2) Action Pause Release Request:
①
How to execute Action Pause Release Request
Execute Action Pause Release Request by any of the following:
▪
Set 1 in I/O parameter No. 35 (input selection function 005 = Action Pause Release
Signal) and ON edge input on input port No.5.
▪
From the software menu, execute Controller (C)
→
Action Pause Release Request (L).
▪
From the mode selection screen of the teaching pendant, select Ctl (Controller operation)
→
Ract (Action Pause Release Request) and execute.
②
Case which requires Action Pause Release Request
Each of the following cases requires executing Action Pause Release Request.
▪
When you set 2 on other parameter No.9 (Deadman SW recovery type = action
continuation recovery [during automatic operation only]), stop according to dead man SW
during automatic operation
→
recover after releasing stop (action pause release).
▪
When you set 2 on other parameter No.10 (emergency stop recovery type = action
continuation recovery [during automatic operation only]), emergency stop during
automatic operation
→
recover after emergency stop release (action pause release).
▪
When you set 2 on other parameter No.11 (safety gate OPEN time recovery type = action
continuation recovery [during automatic operation only]), safety gate OPEN during
automatic operation
→
recovery after safety gate CLOSE (action pause release).
▪
When you set 1 on I/O parameter No.36 (input selection function 006 = pausing action
signal), OFF level input on input port No.6 during automatic operation (pausing action)
→
recover after ON level input on Input port No.6 (action pause release).
* If case (1)
②
and (2)
②
occur at the same time, you need to first execute Driver Power
Recovery Request. After completing it, execute the Action Pause Release Request.
112
Содержание X-SEL
Страница 1: ...X SEL Teaching Pendant Operating Manual Ver 7 0 IAI Corporation ...
Страница 7: ...5 Connection to Controller Mode Switch M cable K J Type Controller 4 ...
Страница 31: ...Go back to the edit screen by pressing the ESC key That s all for inputting basic position data 28 ...
Страница 86: ...Return to the edit screen with the ESC key 83 ...
Страница 124: ...Supplement Exit from the absolute reset mode temporarily with the ESC key without pressing the F1 OK key 121 ...