![IAI ROBO Cylinder RCP5-SA4C Скачать руководство пользователя страница 69](http://html1.mh-extra.com/html/iai/robo-cylinder-rcp5-sa4c/robo-cylinder-rcp5-sa4c_instruction-manual_604040069.webp)
4. Maintenance and Inspection
63
4.2 External Visual Inspection
An external visual inspection should check the following things.
Main unit
Loose actuator mounting bolts, other loose items
Cables
Scratches, proper connections
Stainless steel sheet Scratches
Overall
Irregular noise, vibration
• As a rule of thumb, the stainless steel sheet should last for about 5000km of slider motion.
However, under certain conditions, the stainless steel sheet may need to be replaced earlier.
Generally, replacing the stainless steel sheet will require that you bring the unit to our plant or have one
of our technicians come to your plant to perform the replacement.
• If the actuator is installed vertically, certain conditions may cause grease to drip from the guide. Please
ensure that proper cleaning is performed and grease is replenished.
4.3 Cleaning
• Clean exterior surfaces as necessary.
• Use a soft cloth to wipe away dirt and buildup.
• Do not blow too hard with compressed air as it may cause dust to get in through the gaps.
• Do not use oil-based solvents as they can harm lacquered and painted surfaces.
• To remove severe buildup, wipe gently with a soft cloth soaked in a neutral detergent or alcohol.