Chapter 4 PLC Features
4.1 Device Memory
4-2
ME0416-1A
4.1 Device Memory
In RCON-LC, the device memories are called MO. MO should be classified to three types, bit
memories, word memories and pointers. A bit memory has data volume of 1 bit while a word
memory has that of 16 bits (2 bytes). A pointer does not have data. The number available for use
in each MO and RCON-LC as well as the number available for use in existing models are as
shown below.
Detail of OM and Numbers Available for Use in each Feature
OM Name
OM Type
Purpose
Memory Quantity
(Decimal)
X
Bit Memory
Data Volume: 1 Bit
For Input Assignment
128
Y
For Output Assignment
128
M
For General
3072
LM
For Retention
256
AM
For Axis Control Command
Assignment
4096
SM
For System
128
TS
Timer Contact Status
64
TC
Timer Output Status
64
CS
Counter Contact Status
64
CC
Counter Output Status
64
IX
Word Memory
Data Volume: 16 Bit
For Index
2
D
For General
128
SD
For System
64
TV
Timer Current Value
64
TP
Timer Setting Value
64
CV
Counter Current Value
64
CP
Counter Setting Value
64
L
Pointer
Data Volume: None
For Indication of Destination to
Jump for JE, JMP, CALL
Commands
256
For details regarding the device memory and how to describe, refer to LC Programming Manual
(ME0329) and Ladder Edit Software Manual (ME0330).
Содержание RCON-LC
Страница 2: ......
Страница 18: ...International Standard Compliance Intro 11 ME0416 1A ...
Страница 110: ...Chapter 4 PLC Features 4 3 Error Code 4 24 ME0416 1A ...
Страница 114: ...Revision history Revision history Post 1 ME0416 1A Revision history Revision date Revised content 2020 07 First Edition ...
Страница 115: ......
Страница 116: ......