Chapter 1 RCON-LC System
1.6
Power Capacity
ME0416-1A
1-14
1.6 Power Capacity
[Power Capacity]
The current amperage and the current limit value for LC Unit are the same as those for RCON
Gateway Unit.
Also the current amperages for the PIO/SIO/SCON extension unit and PIO unit are as shown
below.
For the current amperage of RCON-LC System, refer to the current amperage in RCON System
Instruction Manual (ME0384).
Current Amperage of LC Unit, PIO/SIO/SCON Extension Unit and PIO Unit
Item
Specifications
Power supply voltage
DC24V
±
10%
AC200V to 230V
±
10% (Power Supply Unit)
Control power capacity
(per unit)
LC unit
(includes terminal unit)
0.8A
PIO/SIO/SCON
extension unit
0.1A
PIO unit
0.1A
Current Limit Value of LC Unit
Item
Current limit values for selection calculation
Control power (CP)
9.0A or less
Motor power (MP)
37.5A or less