Safety Guide
Intro-6
No.
Operation
Precautions
6 Trial Operation ● When working with two or more persons, make it clear who is to be in charge
and communicate well with each other to ensure safety.
● After teaching or programming, carry out trial operation step by step before
switching to automatic operation.
● When trial operation is to be performed inside the safety/protection fence,
use the same work procedure, determined in advance, as teaching
operation.
● Be sure to confirm program operation at safe speeds. Otherwise, this may
lead to accidents due to unexpected motion caused by program error, etc.
● Do not touch the terminal block or any of the various setting switches while
the equipment is live. Otherwise, this may lead to electric shock or abnormal
operation.
7 Automatic
Operation
● Check before starting automatic operation or restarting after operation stop
that there is nobody within the safety/protection fence.
● Before starting automatic operation, make sure that all peripheral equipment
is ready for automatic operation and that there is no alarm indication.
● Be sure to start automatic operation from outside the safety/protection fence.
● If the product produces abnormal heat, smoke, odor, or noise, immediately
stop it and turn OFF the power switch. Otherwise, this may lead to fire or
damage to the product.
● When a power failure occurs, turn OFF the power switch. Otherwise, this
may lead to injury or product damage due to unexpected product motion
during recovery from the power failure.
8 Maintenance
and
Inspection
● When working with two or more persons, make it clear who is to be in charge
and communicate well with each other to ensure safety.
● Perform the work outside the safety/protection fence, if possible. If operation
must be performed within the safety/protection fence, prepare "Work
Regulations" and make sure that all the workers acknowledge and
understand them well.
● When work is to be performed inside the safety/protection fence, turn OFF
the power switch as a rule.
● When operation is to be performed inside the safety/protection fence,
operators should have emergency stop switches available at hand so that
the unit can be stopped at any time if abnormalities occur.
● When operation is to be performed inside the safety/protection fence, have a
monitor standing by in addition to the operator(s) so that the unit can be
stopped at any time if abnormalities occur. Also, keep watch on the operation
so that a third party cannot operate the switches carelessly.
● Place a sign indicating "Operating" where it can be seen easily.
● For the grease for the guide or ball screw, use appropriate grease according
to the Instruction Manual for each model.
● Do not perform dielectric strength testing. Otherwise, this may lead to
damage to the product.
Содержание ELECYLINDER EC-S13
Страница 2: ......
Страница 9: ...Chapter 12 Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ...
Страница 10: ......
Страница 32: ...1 5 Accessories 1 30 Power I O cable 1 30 Power I O connector 1 31 Motor power supply cable 1 32 ...
Страница 66: ......
Страница 116: ...3 38 3 Wiring ...
Страница 118: ...4 5 Operating method from master device 4 15 Positioning operation ST0 LS0 ST1 LS1 signals 4 15 ...
Страница 136: ...4 18 4 Operation ...
Страница 138: ......
Страница 146: ......
Страница 158: ...6 12 6 Parameters ...
Страница 160: ......
Страница 184: ...7 24 7 Troubleshooting ...
Страница 186: ......
Страница 230: ...8 6 How to replace components 8 44 8 Maintenance and Inspection Fan unit model number PSA FNB ...
Страница 232: ......
Страница 238: ...9 6 9 External Dimensions ...
Страница 240: ......
Страница 244: ...10 4 10 Life ...
Страница 246: ......
Страница 249: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ELECYLINDER Chapter12 ...
Страница 250: ......
Страница 256: ......
Страница 257: ......