4. SCON-CA
214
(* “ON” in the table shows the corresponding bit of “1” and “OFF” shows “0”.)
Signal type Bit Symbol
Contents
Details
Pressing
current-
limiting
value
16-bit
data
-
16-bit integer
Specify the current-limiting value to be used during pressing
operation.
The allowable specification range is 0 (0%) to 255 (100%).
The actual settable range varies depending on each actuator.(Refer
to the catalog or Operation Manual for the actuator.) If a move
command is issued by specifying a value exceeding the maximum
pressing current, an alarm will occur.
4.8 (2)
b15 BKRL Forced brake release: When it is turned ON, the brake is released.
4.6.11 (18)
b14 RMOD
Operating mode selector: The AUTO mode is selected when this
signal is OFF, and the MANU mode is selected when the signal is
ON.
4.6.11 (19)
b13 DIR
Pressing direction specification:
“OFF” for the direction reducing the positioning band from the target
position,
“ON” for the direction adding the positioning band to the target
position
4.6.11 (22)
b12 PUSH
Pressing specification: Positioning operation is performed when this
signal is OFF, and pressing operation is performed when the signal is
ON.
4.6.11 (21)
b11
b10
-
Unavailable
-
b9 CLBR Load cell calibration command: Calibration is performed when this
signal turns ON.
4.6.11 (32)
b8 JOG+ + Jog: “ON” for Movement in the Opposite Direction of Home
4.6.11 (13)
b7 JOG- -Jog: “ON” for Movement to the Home Direction
4.6.11 (13)
b6 JVEL
Jog-speed/inch-distance switching:
The values set in parameter No. 26, “Jog speed” and parameter No.
48, “Inch distance” are used when this signal is OFF, and the values
set in parameter No. 47, “Jog speed 2” and parameter No. 49, “Inch
distance 2” are used when the signal is ON.
4.6.11 (14)
b5
JISL
Jog/inch switching:
Jog operation is performed when this signal is OFF, and inch
operation is performed when the signal is ON.
4.6.11 (15)
b4 SON Servo ON Command: The servo turns ON when this signal turns ON. 4.6.11 (5)
b3
RES Reset: A reset is performed when this signal turns ON.
4.6.11 (4)
b2
STP Pause: A pause command is issued when this signal turns ON.
4.6.11 (11)
b1 HOME Home return: A home-return command is issued when this signal
turns ON.
4.6.11 (6)
P
LC
o
ut
pu
t
Control
signal
b0 DSTR Positioning Command: A move command is issued when this signal
turns ON.
4.6.11 (8)