2.
INTENDED USE
2.1 Operating restrictions
2.1.1 Do not point the working device into yours or someone’s eyes.
2.1.2 Before using, the device should be kept at room temperature for two hours after storing in a cold room or
transporting in wintertime
.
2.2 Device usage
WARNING! It is necessary to charge the battery fully before the first use of the device. The charger is
supplied.
2.2.1 Move the power switch (item 1) to ON position. After device is turned on, the LED starts to flash with a
certain frequency determined by a control program.
At the same time, the green LED will light on the back panel of
the device.
2.2.2. You have to observe the potential location of spy cams through the lens (recommendations can be found in §
2.3). In a place where a camera is installed, you will see bright pulsating points. They are the reverse flares of the
camera lens (see Figure 4). Upon detection of flaring spot, inspect this place closely and identify the source of the
flare.
a)
b)
c)
Figure 4 - view of camera flare in device’s lens (
a – camera hidden in a lamp; b – camera in a purse; c –
CCTV camera in a store)
2.2.3 Battery charge indication. Battery charging
When the device is turned on, the green LED is flashing on the back panel - the battery charge is sufficient and
device is ready to work.
When the device is turned on, the yellow and green LEDS flash alternately - the charge level of the battery is
low, you have to charge the batteries.
When the device is turned on, the yellow LED flashes - the battery is dead, you must charge the battery
immediately.
A Lithium-Ion (Li-ion) battery is used in the device.