EVENT/SENSOR
Use the Event/Sensor menu to set up alarms and relays for cameras.
•
HDD Event:
Use this option to turn SMART alarm on/off and the interval between each SMART
status verification.
•
Alarm In:
Use this option to enable or disable the alarm inputs and set them as normal open (N/O)
or normal closed (N/C)
•
Alarm Out:
Use this option to set up a relay in response to alarms. For each alarm, you can enable
or disable the relay, select whether the relay mode is latched or transparent, and set the delay time.
Figure 41. Alarm Out Event/Sensor Menu
- Type can be HIGH (N/O) or LOW (N/C)
- A
latched
relay continues operating for the duration set.
- A
transparent
relay stops working as soon as the alarm stops being tripped. The delay
time is ignored with transparent relay mode.
- Duration refers to the length of time that the relay remains in effect after the alarm occurs
provided the alarm is in latched mode.
Duration goes into effect when the relay is in
latched mode.
Duration times can be increased by 5 or 10-second increments for the
first minute, and then one- or two-minute increments for a maximum of five minutes.
Duration may also be set to continue until an operator responds and turns off the relay by
pressing any key.
•
Control Device:
It is possible to control up to 254 Veo 120XXN devices with one of an integrated
Joystick/Keyboard device. Configure System ID, set the device’s protocol and Baud Rate. If the
device’s protocol is not available, it is not supported by Veo 120XXN.
Figure 40. Control Device System Menu
24