17
Rev.
150505
i3-TRNG-CAMS-
68R_78R
.indd
3.7 Pendant Pole Mount
1. Use a 3/4” Electrical EMT Conduit
Fitting with a ridgid 3/4” pipe for this
type of installation.
Note on supplied mounting hardware and IP66 rating
Based on installation location and surface type, supplied screws and
anchors may not be adequate. Mounting hardware is site-specific
and may need to be supplied by the installer.
It is the installer’s responsibility to ensure that the mounting surface
is suitable for installation method.
Use sealant at the locations shown on the mounting diagrams to
maintain IP66 rating when installing outside.
Use
silicone
to maintain IP66
rating
DB78BB - Back box
Safety lock screw
3/4” Electrical EMT
Conduit Fitting
Ridgid 3/4” pipe
2. Attach DB78BB back box to the
threaded end of the 3/4” Electrical
EMT Conduit Fitting and rotate
clockwise to attach the two together.
Use silicone sealer as indicated on the
diagram to maintain IP66 rating when
installing outside.
Figure 28. Pendant-Mount - Step 2.
3. Remove the camera cover.
Use a Phillips screwdriver to loosen
the safety lock screw, then grip the
camera cover and flex on one side,
towards the center.
Lift UP to remove.
4. Use a Phillips screwdriver to insert
three machine-type screws provided
with the DB78BB back box into the
screw holes on the back box.
Leave enough screw length
protruding to allow for the camera
body to be rotated onto the screws.
Use
silicone
to maintain IP66
rating
DB78BB - Back box
Safety lock screw
3/4” Electrical EMT
Conduit Fitting
Ridgid 3/4” pipe
Figure 29. Pendant-Mount - Step 4.