background image

 

 

IACER Srl

 

7

 

MNPG148-06 

Characteristics 

Specifications 

Command 

ABS keyboard with 9 keys 

Conditions of use 

Environmental 

temperature 

From +5° to +40°C 

Relative humidity 

From 30% to 75% 

Atmospheric 

pressure 

From 700 to 1060hPa 

Storage and transportation 

conditions 

Environmental 

temperature 

From -10° to +55°C 

Relative humidity 

From 10% to 90% 

Atmospheric 

pressure 

From 700 to 1060hPa 

WARNING

: the device has an output current over 10mA. 

* Use only the battery recharger given by the manufacturer. The use of other 

recharger could seriously compromise the security and safety both of the 

patient and of the device.  

 

Expected useful life of the device is set in 3 years, meanwhile the expected 

useful life of the electrodes is set in 10/15 uses.

 

Device and commands description 

 

1.

 

CH1 output 

2.

 

CH2 output 

3.

 

Battery charger connector  

Содержание MIO CARE PRO

Страница 1: ...USER MANUAL Electrotherapy MIO CARE PRO...

Страница 2: ......

Страница 3: ...WARNING 11 PATIENT PREPARATION 14 DEVICE USE 14 Operating instructions 15 TENS programs 16 Treatment programs for TENS therapy 24 BEAUTY programs 26 Treatment programs for muscles firming up and lipo...

Страница 4: ...and manufactured according to the European Medical Device Directive 93 4 EEC transposed in Italy by the D Lgs 46 97 as modified by the Directive 2007 47 EC D Lgs 37 2010 and further modifications inte...

Страница 5: ...ic Environmental intended use Ambulatory and home MIO CARE PRO is indicated for the treatment and the functional rehabilitation of the following pathologies and anatomical zones wrist articulation han...

Страница 6: ...the medical programs see the following paragraphs related to the detailed description of the programs Caratteristiche tecniche Characteristics Specifications Power supply Rechargeable batteries AAA N...

Страница 7: ...ive humidity From 10 to 90 Atmospheric pressure From 700 to 1060hPa WARNING the device has an output current over 10mA Use only the battery recharger given by the manufacturer The use of other recharg...

Страница 8: ...H2 10 Increase program 11 Decrease program 12 ON OFF and OK button 13 Set programs and therapy pause button 14 Belt clip 15 Battery compartment 1 Mode operation NEMS TENS BEAUTY MEM 2 Wave frequency 3...

Страница 9: ...on Manufacturer Manufacturing date YYYY MM Read instructions for use The product must be disposed as electronic waste in accordance to WEEE Directive on waste electrical and electronic equipment IP22...

Страница 10: ...PRO pack contains n 1 MIO CARE PRO device n 2 connection cables for the transmission of electric impulses n 4 splitting leads n 1 packages containing 4 pre gelled self adhesive 41x41 mm electrodes or...

Страница 11: ...en to use MIO CARE PRO if the patient has a pacemaker is cardiopathic suffers from epilepsy is a pregnant woman is an anxious person has severe disease tuberculosis juvenile diabetes viral diseases in...

Страница 12: ...s and fire It is forbidden to use the device in the presence of patient monitoring equipment of electrosurgical possible bruises and burns or shortwave or microwave therapy equipment or other equipmen...

Страница 13: ...ressure to use pointed or sharp objects on the device keyboard Warning insufficiently sized electrode sections can cause skin reactions or burns do not use damaged electrodes even if they well adhere...

Страница 14: ...connect the electrostimulation cable jacks to the self adhesive electrodes position the self adhesive electrodes on the skin see photos of electrode positions in the Positions manual connect the impul...

Страница 15: ...tic signal advises the user when the treatment is completed 5 Turn off the device keeping pressed the button for at least two seconds FREE MEMORIES ADJUSTABLE PROGRAMS With MIO CARE PRO you can set th...

Страница 16: ...ories according to the mechanism used to reduce the pain The main types are conventional TENS or fast analgesic training TENS or delayed analgesic which is similar to the effect of the electro acupunc...

Страница 17: ...ch the muscles surrounding the treated area begin to contract over this limit the stimulation does not become more effective just more irritating so it is best to stop before that point Programs speci...

Страница 18: ...s Backache sciatic pain Total time 20 min frequency 90 Hz impulse width 50 s Total time 20 min frequency 60 Hz impulse width 60 s 7 Yes Sprains bruises Total time 10 min frequency 110 Hz impulse width...

Страница 19: ...width 150 s Total time 10 min frequency 90 Hz impulse width 50 s 12 Yes Epicondylitis Total time 20 min frequency 90 Hz impulse width 50 s Total time 10 min frequency 70 Hz impulse width 60 s Total t...

Страница 20: ...ce an addictive effect meaning that the impulse will be felt less and less if necessary the intensity can be increased by one level to counter this effect Session duration 40 minutes no less than 30 4...

Страница 21: ...ction of the muscles surrounding the area treated TENS4 Anti inflammatory medical program Program recommended for inflammatory conditions To be applied until the inflammatory state is lessened 10 15 a...

Страница 22: ...Positions manual Intensity to be adjusted between the threshold of perception and pain TENS7 Sprains Bruises medical program The program develops its effectiveness after this type of injury by inhibit...

Страница 23: ...s shown in Figure 1 Intensity to be adjusted between the threshold of perception and pain without causing muscle contraction TENS11 Plantar stimulation medical program This program has a relaxing and...

Страница 24: ...on affecting the fibrous tissues surrounding joints tendons serous sacs and connective tissue These appear altered and can break into fragments and calcify If neglected this condition can become heavi...

Страница 25: ...ENS 3 5 7 Daily up to 2 3 times a day Photo 32 Carpal tunnel syndrome TENS 1 10 12 Daily even twice a day Photo 33 Trigeminal neuralgia TENS 1 10 12 Daily Photo 24 Wryneck TENS 1 TENS 9 8 10 Daily eve...

Страница 26: ...x 7sec 80 1Hz 300 s x 3 sec 100 20Hz 300 s x 5 sec 80 x 60 cycles Total time 10 min 3Hz 300 s x 7sec 80 1Hz 300 s x 3 sec 100 30Hz 300 s x 5 sec 80 x 40 cycles 3 No Toning up upper limbs and trunk Tot...

Страница 27: ...tal time 10 min 3Hz 300 s x 7sec 80 1Hz 300 s x 3 sec 100 60Hz 300 s x 5 sec 75 x 40 cycles Total time 5 min 3Hz 300 s x 7sec 80 1Hz 300 s x 3 sec 100 70Hz 300 s x 5 sec 75 x 20 cycles 7 No Modelling...

Страница 28: ...glutei and hips Total time 4 min frequency 6 Hz impulse width 250 s Total time 20 min 5Hz 250 s x 8 sec ch1 ch2 80 40Hz 250 s x 6 sec ch1 80 40Hz 250 s x 6 sec ch2 80 x 60 cycles Total time 5 min freq...

Страница 29: ...g up lower limbs non medical program These programs are indicated for firming up muscles of the arms and bust BEAUTY1 or the legs BEAUTY2 working mainly on slow twitch fibres It is recommended to thos...

Страница 30: ...Y4 working mainly on fast twitch fibres It is recommended to those who already practice moderate physical activity Method of use 1 identify the muscle to be treated To obtain good results it is best t...

Страница 31: ...ensity should be gradually increased so that muscle contractions are not painful 5 during contraction generated by the unit contract the muscle voluntarily A cycle of 15 20 applications must be comple...

Страница 32: ...2 Lipolysis abdomen 9 thighs 10 glutei and hips 11 arms 12 non medical program These specific drainage programs increase microcirculation within and around the muscle fibres treated and create rhythmi...

Страница 33: ...BEAUTY15 Heaviness in legs non medical program This program is used to improve blood flow and muscle oxygenation speeding up the elimination of lactic acid produced after anaerobic sessions for muscle...

Страница 34: ...UTY1 BEAUTY1 5 Lipolysis abdomen Photo 20 BEAUTY6 BEAUTY 11 BEAUTY6 BEAUTY1 6 Lipolysis thighs Photo 21 BEAUTY7 BEAUTY 11 BEAUTY7 BEAUTY1 6 Lipolysis glutei Photo 19 BEAUTY8 BEAUTY 11 BEAUTY8 BEAUTY1...

Страница 35: ...1Hz 200 s x 3 sec 100 30Hz 200 s x 8 sec 80 x 45 cycles 3 No Resistance lower limbs Total time 4 min Frequency 6 Hz impulse width 300 s Total time 15 min 3Hz 300 s x 9sec 80 1Hz 300 s x 3 sec 100 20Hz...

Страница 36: ...time 4 min Frequency 6 Hz impulse width 300 s Total time 10 min 3Hz 300 s x 7sec 80 1Hz 300 s x 3 sec 100 50Hz 300 s x 5 sec 75 x 40 cycles Total time 10 min 3Hz 300 s x 7sec 80 1Hz 300 s x 3 sec 100...

Страница 37: ...min Frequency 6 Hz impulse width 300 s Total time 10 min 3Hz 300 s x 12sec 90 1Hz 300 s x 3 sec 100 100Hz 300 s x 5 sec 80 x 30 cycles Total time 10 min 3Hz 300 s x 12sec 90 1Hz 300 s x 3 sec 100 120H...

Страница 38: ...l tonic contractions lower limbs Total time 3 min Frequency 6 Hz impulse width 300 s Total time 10 min 30Hz 300 s x 5 sec 80 CH1 30Hz 300 s x 5 sec 80 CH2 x 60 cycles Total time 5 min Frequency 4 Hz i...

Страница 39: ...0 Total time 10 min Frequency 2 Hz impulse width 250 s 20 No Deep massage Total time 5 min Frequency 3 Hz impulse width 250 s Total time 10 min 3Hz 250 s x 2 sec ch1 100 3Hz 250 s x 2 sec ch2 100 x 15...

Страница 40: ...useful for sports involving maximum effort right from the start Suitable for all muscle groups Session duration 16 minutes Electrodes positioning photo from 01 to 23 21 excluded of the Positions manua...

Страница 41: ...ntractions alternate with periods of active recovery during the work phase allowing the muscle to be trained without subjecting it to stress and improving oxygenation of the same muscle The following...

Страница 42: ...ighest that can be endured in order to obtain maximum muscle exertion whilst involving the greatest number of fibres NEMS12 Deep capillarization non medical program This program significantly increase...

Страница 43: ...n duration 24 minutes Electrodes positioning photo from 02 to 05 and 11 12 of the Positions manual Intensity during contraction has to be adjusted so that the contraction intensity is the same as a vo...

Страница 44: ...ding training sessions in particular after long and intense exertion to be used immediately after exertion This program helps drainage and capillarization improving muscle oxygenation and helping to d...

Страница 45: ...y training program No of weeks Day 1 Day 3 Day 5 Day 7 Abdominal muscles basic strength Photo 1 20 FITNESS6 FITNESS19 FITNESS6 FITNESS6 FITNESS12 5 Pectoral muscles basic strength Photo 7 17 FITNESS6...

Страница 46: ...1 90 min frequency 1 200 Hz contraction time 1 10 sec slope 0 5 sec recovery time 0 30 sec width impulse 50 450 s 13 No Battery test M1 M5 TENS Free memories medical program Free memories for antalgi...

Страница 47: ...leanliness of the device Device not subject to sterilization Note Never use solvents for cleaning Cleaning agents cause damage to the device Attention to the need for periodic maintenance especially i...

Страница 48: ...turer Here below are some typical situations MIO CARE PRO cannot be turned on and or the display does not light up Check the battery status and replace it if it is necessary make reference to chapter...

Страница 49: ...into the power socket The display will show the battery blinking icon and the TIME min icon which takes account of the charging time on the display After 4 hours the recharge automatically finishes an...

Страница 50: ...vice is not used Discharge the battery as much as possible before the recharging Use only the original battery charger or in any case the battery charger supplied by the fabricant distributor Not open...

Страница 51: ...ed to intervene promptly if necessary as a result of manufacturing defects The warranty conditions are those described in the following paragraph Warranty conditions The warranty is provided by IACER...

Страница 52: ...ce For any technical assistance contact I A C E R S r l Via Enzo Ferrari 2 30037 Scorz VE Tel 041 5401356 Fax 041 5402684 Technical documentation related to repairable parts could be attached but only...

Страница 53: ...careful when applying therapy to patients with pacemakers In any case it is recommended to use the equipment at least at 3 meters away from televisions monitors cellphones or any other electronic equi...

Страница 54: ...IACER Srl 54 MNPG148 06 For more details please see the EMC tables at the end of this manual...

Страница 55: ...ectromagnetic environment guidance RF emissions CISPR 11 Group 1 MIO CARE PRO uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any inte...

Страница 56: ...hat of a typical commercial or hospital environment 1kV for input output lines 1kV for input output lines Impluses IEC 61000 4 5 0 5kV 1kV Line s to line s 0 5kV 1kV Line s to line s Mains power quali...

Страница 57: ...onment specified below The customer or the user of the device should assure that it is used in such an environment Immunity test Test level EN 60601 Conformity level Electromagnetic environment guide...

Страница 58: ...apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed RF transmitters such as base stations for...

Страница 59: ...itter m from 150kHz to 800 MHz from 80MHz to 800 MHz from 800MHz to 2 7GHz 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output p...

Страница 60: ......

Отзывы: