![I-Tech 17908 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/i-tech/17908/17908_user-manual_603054019.webp)
IACER Srl
19
MNPG118-02
Some patients might be particularly sensitive to ultrasound and might
therefore experience undesired reactions such as hot flushes in the treated
area. Check the treated area before, during and after the treatment and
suspend it in case of undesired effects.
Make sure that the handpiece is in contact with the skin using a specific
ultrasound gel. Any substance used for this purpose must be highly conductive.
Air is a terrible conductor of ultrasound waves.
Patients with arterial or venous thrombosis or thrombophlebitis are at risk of
developing embolisms when electrical stimulation is applied over or adjacent
to the vessels containing the thrombus.
With ultrasound therapy inflammation temporary increases can happen in
treatment area, and so pain temporary increase, traumas due to more dosage,
nervous system reactions, sanguine coagulation. If this occurs, suspend the
treatment and consult a doctor.
The long-term effects of chronic electrical stimulation are unknow. Pay
attention, electrical stimulation is not a substitute for pain medications and
other pain management therapies.
Since the effects of stimulation of the brain are unknown, stimulation should
not be applied across the head, and electrodes should not be placed on
opposite sides of the head.
No significant side effects related to electrotherapy are known. In some cases
of particularly sensitive people, after the treatment, redness of the skin near
the electrodes: the redness usually disappears a few minutes after the
treatment. If the redness persists, consult a doctor.
Patients may experience headache and other painful sensations during or
following the application of electrical stimulation near the eyes, head and face.
In some rare cases evening stimulation causes some difficulties in falling
asleep. In this case, suspend the treatment and consult a doctor.
Warnings
It is recommended:
•
to control position and meaning of all the labels and symbols on the
equipment;
•
the device doesn’t produce or receive electromagnetic interferences from
other devices. However, it’s recommended to keep a distance of at least 3
meters from televisions, monitor, mobile phones or other electronic
devices (which can lead to abnormal device behavior). Care must be taken
when operating this equipment around other equipment. Potential
electromagnetic or other interference could occur to this or to the other
equipment;
Содержание 17908
Страница 1: ...USER MANUAL Ultrasound therapy and electrotherapy...
Страница 2: ......
Страница 4: ...IV ELECTROMAGNETIC INTERFERENCES AND ELECTROMAGNETIC COMPATIBILITY TABLES 50...
Страница 15: ...IACER Srl 15 MNPG118 02 Labelling 1 Ultrasound head 2 LED for head skin detection 3 Handle applicator...
Страница 55: ......
Страница 56: ......