11-1-2.Female Connector
①
Do not recommend to perform a conductivity test using the mated male connector.
If the same male connector is used for conductivity test, the connectors are repeatedly mated and unmated, and the male terminal could be bent.
These may cause of the female terminal spring deformation, or the contact failure caused by adhesion the particles of friction according to excessive
insertion and removal actions.
②
To test electrical conductivity of female connector, place a probe pin at prescribed point (0.5N MAX.) on outside of the female terminal.(see Fig.44)
③
Do not insert a probe pin into female terminal box, as this may damage the female terminal spring.
Do not use female terminal, if the probe pin has been inserted. Replace the female terminal.
④
Probe pin must be bigger than the gap between female housing and female terminal.(see Table 6)
⑤
Once tested, check there is no deformation (e.g. collapse, etc.) of female housing.
Female Terminal
Part No.
VT004-513
0.65mm
Φ0.75mm (0.70
~
0.85mm)
Recommended Probe Pin Diameter
Gap between Housing and Terminal
VT001-512
0.50mm
Φ0.60mm (0.55
~
0.70mm)
1.5mm
Terminal
Tab Size
0.5mm
Reference
:
Probe Pin position on Female Connector
①
Part No.
:
VT001-512(Terminal Tab Size
:
0.5mm)
②
Part No.
:
VT004-513(Terminal Tab Size
:
1.5mm)
Housing thickness
Recommennded Probe Pin Diameter
Distance between Probe Pin
Distance between Housing bottom surface of Probe Pin
Gap betweem Housig and Terminal
Housing thickness
Recommennded Probe Pin Diameter
Distance between Probe Pin
Distance between Housing bottom surface of Probe Pin
Gap betweem Housig and Terminal
Table 6.Recommended Probe Diameter.
Fig 45. Conductivity test for female terminals (contacts)
Place the probe pins on the red areas