6.How to release the retainer
①
Insert a screwdriver with a width of 1.0mm to 1.5mm into the releasing jig aperture (2 places) in
the bottom surface of the female housing, and push out the retainer. (see Fig.30).
Notes
①
Do not use the screwdriver for any other part of the housing other than the releasing apertures. Doing so may cause damage or reduced
performance.
②
Completed at the position where the releasing apertures comes out from the bottm surface of the female housing.
Therefore must not release the retainer anymore.
It may cause damage or deformation of the female housing.
③
Check for any deformation or damage on both of the retainer and the female housing after releasing the retainer,
before continuing any operation.
④
If there is any damage or deformation, do not use it.
Replace the item with a new one.
⑤
Only use the specified screwdriver for releasing the retainer.
⑥
Do not use screwdriver with damage or deformation.
Fig 30. How to release the retainer
Direction of
release
Releasing jig aperture