Description of faults
:
Excessive conductors out & Incomplete conductors crimping.
Please make sure there is no excessive conductors out and incomplete conductors crimping.
When the retainer is inserted, excess conductors could be caught in the gap between the female housing
and the retainer. Therefore there is a possibility of defects such as failure to be locked or short circuit
between adjacent female terminals. (see Fig.21)
(
5
)
Incomplete insulation crimping
Strip length is too short and insulation is crimped inside the wire barrel (see Fig.22).
Strip length is too long and insulation does not fit completely inside the insulation barrel (see Fig.23).
(
6
)
Torn insulation
Insulation is torn by insulation barrel. (see Fig.24)
Catching and Short circuit caused by excess conductors
Fig 21.Defect by excess conductors
Excessive conductors out
Fig 22.Strip too short
Fig 23.Strip too long
Fig 24. Torn insulation
Torn insulation caused
by insulation crimping.