ISHVW CONNECTOR Instruction Manual
Document No.
HDM-0012
7
/
29
Confidential C
(1)-2. Measuring method for insulation barrel crimp height is described below.
To measure the insulation barrel crimp height, pinch the top of the insulation barrel (winding side) and the bottom of
the insulation barrel with a micrometer. (see Fig.8)
Secure terminals firmly to obtain accurate measurement.
(1)-3. Measuring method for wire barrel crimp width is described below.
To measure the wire barrel crimp width, pinch the side of the wire barrel with a micrometer. (see Fig.9)
Secure terminals firmly to obtain accurate measurement.
Fig 9. Wire barrel crimp width measurement
Fig 8. Insulation barrel Crimp height measurement
MALE TERMINAL
FEMALE TERMINAL
Section
Micrometer
Section
Micrometer
Section
Micrometer
Section
Micrometer
FEMALE TERMINAL
MALE TERMINAL