ISHVW CONNECTOR Instruction Manual
Document No.
HDM-0012
26
/
29
Confidential C
10.Handling of Product
10-1.Conductivity test
10-1-1.Female connector
①
Do not recommend to perform a conductivity test using the mated male connector.
If the same male connector is used for conductivity test, the connectors are repeatedly mated and unmated, and the male terminal could be
bent. These may cause of the female terminal spring deformation, or the contact failure caused by adhesion the particles of friction according
to excessive insertion and removal actions.
②
To test electrical conductivity of female connector, place a probe pin at prescribed point (0.5N MAX.) on
outside of the female terminal. (See Fig. 48)
③
Do not insert a probe pin into female terminal , as this may damage the terminal spring.
Do not use female terminal, if the probe pin has been inserted. Replace the female terminal.
④
Probe pin must be
φ0.55
~
0.70mm.
Must not be smaller than the gap between female housing and female terminal (0.5mm).
⑤
Once tested, check there is no deformation (e.g. collapse, etc.) of female housing.
Female terminal
Plobe pin
Female housing thickness
Gap between female housing and
female terminal
Distance between housing bottom
surface of probe pin.
Distance between probe pin
Recommended probe pin diameter
[Φ0.60
mm(
Φ0.55
mm
~
Φ0.70
mm)]
The probe pin must contact this part of
the female terminal.
Fig.48 Conductivity test for female terminals (contacts)
Fig.49
【
Reference
】
Probe pin position on female connector