10-1-2. Male connector
①
When carrying out conductivity test of the male connector, place the probe pin on the end of the male terminal (Load:0.5N MAX.).
(see Figs. 50)
If load 0.5N and more, male terminal(s) may be damaged.
②
If there is any damage or deformation, do not use the damaged item. Replace the item with a new one.
10-2. Arrangement of Wires
①
When arranging the wires to sideways, keep the wires in straight (at least 15mm) from the connector to avoid excessive stress to
the housing sidewalls and terminals or the terminal leaning inside the housing as shown in Fig.51.
②
Once straight portion is secured, arrange the wires with adequately large R.
Place the probe pin on the end of the male terminal
Fig.50 Conductivity test for male terminals (contacts)
Fig.51 Arrangement of wires
Wire straight portion
Female connector