i-onyx VN-855V5 Скачать руководство пользователя страница 14

 

10

2.  Select the camera from the list and then select the driver, 

ViconMenu.dll

. The ViconMenu will display. 

Select the Menu button for the menu to display. Follow the onscreen instructions to navigate the menu 

system or refer to the instruction manual for the camera. 

Note: The camera defaults to DIP switch settings. The PRIORITY setting in the SPECIAL menu must be set 

to REMOTE in order to set the OSD settings. This must be done the first time on every camera in the 

system. 

 

 

ViconNet GUI for VN-855WDR OSD Menu 

 

  XX181-05-00 Rev 1208 VN-855V5 IP Camera 

 

Содержание VN-855V5

Страница 1: ...ose Warning To prevent fire or shock hazard do not expose the unit to rain or moisture Copyright 2008 Vicon Industries Inc All rights reserved Product specifications subject to change without notice Vicon and its logo are registered trademarks of Vicon Industries Inc ViconNet Kollector I Onyx and their logos are registered trademarks of Vicon Industries Inc VICON INDUSTRIES INC 89 ARKAY DRIVE HAUP...

Страница 2: ......

Страница 3: ...ment off and on the user is encouraged to try and correct the interference by one or more of the following measures Reorient the receiving antenna Relocate the equipment with respect to the receiver Relocate the equipment away from the receiver Plug the equipment into a different electrical outlet so that the equipment and receiver are on different branch circuits If necessary the user should cons...

Страница 4: ......

Страница 5: ...Safeguards ii Precautions 2 Connectors and Controls 4 OSD Menu for VN 855WDR 8 ViconNet Configuration 15 Shipping Instructions 27 Coaxial Cable Recommendations 28 Twisted Pair Cable 29 Network Cable 30 Technical Information 29 Vicon Standard Equipment Warranty 32 ...

Страница 6: ...re they will be pinched or used to bear weight Allow some slack in the cord where it enters the unit 12 Lightning Disconnect the product from its power source and cable system when possible to prevent damage due to lightning and power line surges 13 Power Lines Do not locate outside cables over power or utility lines where they can fall and make direct contact Contact with power lines can be fatal...

Страница 7: ... toward the sun Use caution when operating the camera in the vicinity of spot lights or other bright lights and light reflecting objects 7 Do not operate the camera beyond its temperature humidity or power source ratings Do not use the camera in an extreme environment where high temperature or high humidity exists Use the camera under conditions where temperatures are between 14 F 122 F 10 C 50 C ...

Страница 8: ...4 CONNECTORS AND CONTROLS High Resolution Model VN 855 Day Night Model VN 855DN WDR Model VN 855WDR XX181 05 00 Rev 1208 VN 855V5 IP Camera ...

Страница 9: ...to a relay device the electrical specifications are open drain output accepts voltages up to 5 5 V 24 mA output drive at 3 3 V non inductive 4 VIDEO OUT CH1 1 0 V p p 75 ohm composite video signal is provided at this BNC connector 5 MODE SELECT SWITCH This switch varies according to model Note The camera defaults to DIP switch settings The PRIORITY setting in the SPECIAL menu must be set to REMOTE...

Страница 10: ...in the picture may be seen out of focus Note When adjusting the focus it is recommended that the iris be completely open a dark condition either at night or using a filter so that the depth of field does not influence the adjustment 4 Fixed iris or manual iris lenses may be used with the linear shutter EE ELC mode when the scene brightness varies over a limited range 5 Do not use the EE ELC mode w...

Страница 11: ...5 AGC MAX ON OFF Switch OR DAY NIGHT ON OFF Switch VN 855DN only The automatic MORE GAIN function automatically adjusts picture gain in accordance with the brightness of the subject This function is enabled when set to ON For the VN 855DN camera the day night function can be turned ON or OFF 6 AUTOIRIS LENS CONNECTOR FOR DC DRIVE LENS This connector supplies the control signals to the DC drive aut...

Страница 12: ... CAP Remove this cap before installing the lens Do not handle or leave the camera with cap off 12 BACKFOCUS ADJUSTMENT This is used to position the CCD image sensor at the precise point of focus the lens Backfocusing Fixed Focal Length Lenses 1 Install a lens and connect the camera to a monitor and power supply 2 Open the iris completely If an autoiris lens used reduce the room lighting to allow t...

Страница 13: ...ettings for the VN 855WDRV4 camera can also be done from an OSD menu system after the camera is setup in the ViconNet system ViconNet setup procedure follows Refer to the most current ViconNet manual XX113 0X for detailed instructions on using ViconNet Configuration of the VN 855WDR is done through the ViconNet GUI Prerequisites for using this procedure with the VN 855WDR are ViconNet version 4 an...

Страница 14: ...instructions to navigate the menu system or refer to the instruction manual for the camera Note The camera defaults to DIP switch settings The PRIORITY setting in the SPECIAL menu must be set to REMOTE in order to set the OSD settings This must be done the first time on every camera in the system ViconNet GUI for VN 855WDR OSD Menu XX181 05 00 Rev 1208 VN 855V5 IP Camera ...

Страница 15: ... WDR OFF BLC WDR AWB ATW1 ATW2 AWC MANUAL SPECIAL EXIT QUIT SAVE PRESET ELC level setting BLC level and zone setting SHUTTER SPEED AGC FLICKERLESS setting SHUTTER SPEED AGC FLICKERLESS setting MANUAL RED BLUE value setting BLEMISH PRIORITY POSI NEGA SHARPNESS BLC WDR BW MANUAL MANUAL LENS MANUAL4 WDR OFF DAY NIGHT COLOR4 AWB ATW1 SPECIAL 4 EXIT QUIT Use AP to select Main Menu COLOR WDR level setti...

Страница 16: ...following screen adjust the brightness level using Pan Left Right WDR Wide Dynamic Range WDR Using this function both the indoor and outdoor scenes display clearly Select WDR using Tilt Up Down and press AP key Select the Level with Pan Left Right ELC LEVEL 80 WDR LEVEL 74 LENS MANUAL4 WDR OFF DAY NIGHT COLOR4 AWB ATW1 SPECIAL 4 EXIT QUIT Use AP to select LENS MANUAL4 WDR WDR DAY NIGHT COLOR4 AWB ...

Страница 17: ...de only Otherwise the display as N A When Manual mode is selected in Lens Menu set up of Shutter and Flickerless is not available Shutter mode Supports 9 levels between 1 100 sec 1 50 000 sec AGC mode Automatic Gain can be setup as High Low Off using Pan Left Right In a dark environment when AGC gain is set to high the image becomes brighter Flickerless mode When ON shutter speed is fixed at 1 100...

Страница 18: ...ording to environment In AWB menu 4 levels ATW1 ATW2 AWC Manual can be setup ATW 1 White Balance is automatically adjusted in the range of 2500K 7500K degrees ATW 2 White Balance is automatically adjusted regardless of the range of color temperature BW SHUTTER OFF AGC HIGH FLICKERLESS OFF LENS MANUAL4 WDR OFF DAY NIGHT BW4 AWB ATW1 SPECIAL 4 EXIT QUIT Use AP to select LENS MANUAL4 WDR OFF DAY NIGH...

Страница 19: ...reen In R Gain and B Gain modes the value of Red and Blue can be controlled using the keypad Considering the change of color select proper values and fix color temperature Caution Auto White Balance function can work incorrectly in high temperature bright sky sunset darkness or drastic change of light LENS MANUAL4 LENS MANUAL4 WDR OFF WDR OFF DAY NIGHT COLOR4 DAY NIGHT COLOR4 MANUAL AWB R GAIN 68 ...

Страница 20: ...enu system This must be set before making any other menu selections for the settings to take effect When setting to DIP SW menu setting values will not be applied Use the DIP switch on the rear of the camera for settings POSI NEGA In Posi Nega mode brightness of video shows normal reverses to negative image Sharpness In Sharpness mode outline of video image can be controlled At high level outline ...

Страница 21: ...ons can be used for live viewing and recording of network streamed video A network can be as simple as a single VN 855 camera connected to a ViconNet Workstation or can be complex with the addition of several networks interconnected via WAN When adding a VN 855 IP Camera to the ViconNet network the following items must be considered The number of cameras on a switch with respect to switch capabili...

Страница 22: ...255 255 0 Gateway address 1 1 1 1 Gateway address 1 1 1 1 On first startup the camera will attempt to establish connection to the Nucleus with the default address 1 1 1 1 Connecting it to an active Nucleus is done through the VNSetup utility Note When connecting to ViconNet application version 5 the number of concurrent users viewing video from the same device cannot exceed 10 users Groups and Use...

Страница 23: ...19 IMPORTANT NOTE XX181 05 00 Rev 1208 VN 855V5 IP Camera ...

Страница 24: ...e desktop for future use 1 Make sure the MAC address and password of the camera is available Use MAC Address log provided 2 Verify that the camera is physically connected to the configuring workstation via the network Setup TAB Note Since the Setup configuration affects the entire installation process it MUST be configured first In the Setup TAB 3 fields are defined The Upgrade files field indicat...

Страница 25: ...te This is correct for BIOS from version 1 0 10 86 and later ViconNet version 3 3 Password authentication There are two authentication options You can either authenticate a specific unit by entering its password or use a Nucleus authentication allowing you access to all units in the network 3 1 Unit authentication On the Unit password field enter the unit password and press the Add password button...

Страница 26: ...vel on a scale of 0 4 where 4 is most information Note The Apply button must be pressed for changes to take effect Note Verify all IP addressing parameters with your IT administrator Note In order for the DHCP option to work properly verify that the server does not expire the IP address licensed to the camera Camera should always receive the same IP address from the DHCP server Unit XX181 05 00 Re...

Страница 27: ...Install TAB The Install TAB allows the user to install upgrade newer versions Install Info Tab The Info TAB displays the selected IP product general information Info XX181 05 00 Rev 1208 VN 855V5 IP Camera ...

Страница 28: ...ing of application is disabled The Disable load button allows the pausing of the application load in case of software issues while still permitting communication via VNSetup the Enable load button resumes the application load Advanced Custom TAB The Custom TAB allows setup of the VOX settings The VOX mechanism allows setting the IP device so that it will not transmit audio if the level it too low ...

Страница 29: ...ion server or recorder are available as follows A network settings screen is used to modify the camera s IP parameters This allows great flexibility in network setup Note This setup can be performed from any VN WS VN NVR workstation connected to the camera and to the Nucleus or from a Kollector Elite 1 Verify that the camera is connected to the network that it is active and that it is configured t...

Страница 30: ...pported by the ViconNet system through a workstation recorder or server 1 System macros can be configured to view and record the camera s video In addition within macros alarms can be sent and remote macros triggered 2 An alarm can be triggered upon video motion detection and video loss This alarm can be sent remotely to other networked units Refer to the ViconNet workstation manual XX113 3X for c...

Страница 31: ...y Fareham PO15 5TX United Kingdom Phone 44 0 1489 566300 Fax 44 0 1489 566322 2 Attach a sheet of paper to the unit with the following information a Name and address of the company returning the unit b Name of the Vicon employee who issued the R A c R A number d Brief description of the installation e Complete description of the problem and circumstances under which it occurs f Unit s original dat...

Страница 32: ...ance and better video quality with increased difficulty in handling and installation Let the required picture quality and cable distance provide a guide in choosing the best cable type For cables other than the approved Vicon types below contact the manufacturers listed below Note that BC refers to bare copper and TC refers to tinned copper Recommended Coaxial Cable Types Cable Type Belden Type No...

Страница 33: ...for RS 422 RS485 applications Single individually shielded twisted pair is also a suitable cable Choose a Belden cable type by referring to the characteristics and maximum distances listed below The maximum distance for the most reliable digital control refers to the distance between the CPU Keypad and the Camera Assembly The characteristics of the cables in Table 6 should be used as a guideline w...

Страница 34: ...cations Choose a Belden cable type by referring to the characteristics listed below The Table below should be used as a guideline when cables other than Belden are used Materials and construction must follow the guidelines above CABLE TYPE WIRE SIZE AWG INSULATION MATERIAL JACKET MATERIAL CATEGORY BANDWIDTH MHz MAXIMUM DISTANCE ft m NUMBER OF TWISTED PAIRS Belden 1624P 24 Flourinated Ethylene Prop...

Страница 35: ...lements 1 over LAN connection PAL 752 H x 582 V VN 855 VN 855WDR Sensitivity NTSC and PAL model 0 09 fc 1 0 lux at standard gain dependant 0 07 fc 0 7 lux at high gain VN 855DN 30 fps 25 fps PAL 0 0009 fc 0 01 lux in night mode 0 07 fc 0 7 lux in day mode Conditions lens at f 1 2 and 40 IRE video output Maximum 10 viewing recording streams per camera Horizontal VN 855 N 855DN 540 lines Resolution ...

Страница 36: ...er than 52 dB Automatic 1 0 V p p VBS 75 ohms composite video Internal Automatic AGC ON OFF select DC drive coil CS G autoiris lenses Power Indicator Red LED Ethernet Indicators Green LED Network connectivity Amber LED Network activity Status Indicator Blue LED blinks when camera is live ALC Level potentiometer Mode Select DIP Switch model dependent BLC WDR ON OFF ALC ELC AI EE AGC ON OFF FLICKERL...

Страница 37: ...ent showing abuse or damage or to parts which in the judgment of the Company are not defective or any equipment which may have been tampered with altered misused or been subject to unauthorized repair Software supplied either separately or in hardware is furnished on an As Is basis Vicon does not warrant that such software shall be error bug free Software support via telephone if provided at no co...

Страница 38: ...rs Brunel Way Fareham PO15 5TX United Kingdom 44 0 1489 566300 Fax 44 0 1489 566322 Germany vin videotronic infosystems gmbh Lahnstrasse 1 D 24539 Neumuenster Phone 49 0 4321 8790 Fax 49 0 4321 879 97 Far East Office Unit 5 17 F Metropole Square 2 On Yiu Street Shatin New Territories Hong Kong 852 2145 7118 Fax 852 2145 7117 Internet Address www vicon cctv com ...