i-MO 540 Series Скачать руководство пользователя страница 11

EMS i-MO 540 Series Hardware Installation Guide

 

Version 

2.0

 

 

 

ELECTRONIC MEDIA SERVICES LIMITED

   

PASSFIELD BUSINESS CENTRE, LYNCHBOROUGH ROAD, LIPHOOK, HAMPSHIRE, GU30 7SB, UK

 

Tel:

 01428 751655 | 

Fax:

 01428 751654 | 

E-mail:

 [email protected]

 

Page 

11

 of 

18

 

 

Appendix A - WiFi Radio Component 

Warnings 

When using the device, ensure that the antenna of the device is at least 1 cm away from all persons. 

Do not use the device where using wireless devices is prohibited or may cause interference or danger. 

Do not operate the WiFi device in areas where blasting is in progress, where explosive atmospheres may be 
present, near medical equipment, life support equipment, or any equipment which may be susceptible to any 
form of radio interference. In such areas, the WiFi device MUST BE POWERED OFF. It can transmit signals 
that could interfere with this equipment. 

Do not operate the WiFi device in any aircraft, whether the aircraft is on the ground or in flight. In aircraft, the 
WiFi device MUST BE POWERED OFF. When operating, it can transmit signals that could interfere with 
various on-board systems. 

Regulatory Notices 

The design of the WiFi device complies with U.S. Federal Communications Commission (FCC) guidelines 
respecting safety levels of radio frequency (RF) exposure for mobile devices, which in turn are consistent 
with the following safety standards previously set by U.S. and international standards bodies: 

 

ANSI / IEEE C95.1-1999, IEEE Standard for Safety Levels with Respect to Human Exposure to 
Radio Frequency Electromagnetic Fields, 3kHz to 300 GHz 

 

National Council on Radiation Protection and Measurements (NCRP) Report 86, 1986, Biological 
Effects and Exposure Criteria for Radio Frequency Electromagnetic Fields 

 

International Commission on Non-Ionising Radiation Protection (ICNIRP) 1998, Guidelines for 
limiting exposure to time-varying electric, magnetic, and electromagnetic fields (up to 300 GHz) 

FCC ID: N7N-MHS802

 

RF Exposure - This device has been tested for compliance with FCC RF exposure limits in a portable 
configuration. At least 1.0 cm of separation distance between the WiFi Antenna and the user's body must be 
maintained at all times. This device must not be used with any other antenna or transmitter that has not been 
approved to operate in conjunction with this device. 

WARNING (EMI) - United States FCC Information - This equipment has been tested and found to comply 
with the limits for a Class B computing device peripheral, pursuant to Parts 15 and 27 of the FCC rules. 
These limits are designed to provide reasonable protection against harmful interference in a residential 
installation. 

This equipment generates, uses, and can radiate radio frequency energy. If not installed and used in 
accordance with the instructions, it may cause harmful interference to radio communications. However, there 
is no guarantee that interference will not occur in a particular installation. 

If this equipment does cause harmful interference to radio or television reception, which can be determined 
by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more 
of the following measures: 

 

Reorient or relocate the receiving antenna. 

 

Increase the separation between the equipment and receiver. 

Содержание 540 Series

Страница 1: ...Hardware Installation Guide i MO 540 Series Bonding Router Hardware Installation Guide for the i MO 540 Series Appliance...

Страница 2: ...bility 5 AC Power Electrical Safety Guidelines 5 Hardware Installation Guide 6 1 Installing the Rack mount kit optional 6 2 Attach WiFi antennas optional 6 3 Attach 3G 4G antennas and cables 7 4 Attac...

Страница 3: ...A SERVICES LIMITED PASSFIELD BUSINESS CENTRE LYNCHBOROUGH ROAD LIPHOOK HAMPSHIRE GU30 7SB UK Tel 01428 751655 Fax 01428 751654 E mail imo ems uk com Page 3 of 18 I MO Appliance Identification Guide Th...

Страница 4: ...erly grounded Do not open or remove chassis covers or sheet metal parts unless instructions are provided in this documentation Such an action could cause severe electrical shock Do not push or force a...

Страница 5: ...network cabling with a good distribution of grounding conductors If you must exceed the recommended distances use a high quality twisted pair cable with one ground conductor for each data signal when...

Страница 6: ...entering this URL http tinyurl com lt297hl 1 Installing the Rack mount kit optional This stage is only required if you plan to mount the appliance in a communications rack The rack mount kit includes...

Страница 7: ...etre apart from each other The connector on each aerial cable should be attached to the aerial sockets 1 3 as shown below Note Connectors should be touch tight only Do not over tighten 4 Attach networ...

Страница 8: ...of the appliance as illustrated below Note Please ensure you insert the SIM cards carefully in their slots and ensure that they are pressed in as illustrated above Note Up to six SIMs can be inserted...

Страница 9: ...switch the unit on the power switch should be set to the on position 1 The power switch at the front of the unit is used to turn the appliance on boot or off shutdown As soon as the button is pressed...

Страница 10: ...lash when the appliance is Transmitting or Receiving data Mobile Status This shows the status of each mobile channel The letter U will be displayed when the link is UP and D is displayed when the link...

Страница 11: ...etic Fields 3kHz to 300 GHz National Council on Radiation Protection and Measurements NCRP Report 86 1986 Biological Effects and Exposure Criteria for Radio Frequency Electromagnetic Fields Internatio...

Страница 12: ...ternational Commission on Non ionizing Radiation Protection ICNIRP and include safety margins designed to assure the protection of all persons regardless of age and health The guidelines use a unit of...

Страница 13: ...CHBOROUGH ROAD LIPHOOK HAMPSHIRE GU30 7SB UK Tel 01428 751655 Fax 01428 751654 E mail imo ems uk com Page 13 of 18 WiFi Radio Aerial 2 x WiFi Aerial Technical Data GSM GSM 850 900 824 960 MHz GSM 1800...

Страница 14: ...GSM 1800 MHz 1710 1990 MHz UMTS 2 1 GHz 1900 2170 GHz Gain 5 dBi Polarization vertical Rod Length 290mm Power maximum 20 W Cable length 2500 mm Cable type RG 174 Connector SMA male VSWR 1 5 Technical...

Страница 15: ...dcast pattern To achieve this pattern the antenna should be mounted clear of any obstructions to the sides of the radiating element If the mounting location is on the side of a building or tower the a...

Страница 16: ...is device is subject to the Waste from Electrical and Electronic Equipment WEEE directive of the European Union The reason for separating WEEE and batteries from other waste is to minimize the potenti...

Страница 17: ...or paying all parts labour and shipping charges The warranty described above shall apply to all repaired or replaced Product for a period of 90 days from the date of return to you or the balance of th...

Страница 18: ...DVISED OF THE POSSIBILITY OF SUCH DAMAGES OR THEY ARE FORESEEABLE OR FOR CLAIMS BY ANY THIRD PARTY MAXIMUM AGGREGATE LIABILITY OF THE AFOREMENTIONED PERSONS SHALL NOT EXCEED THE AMOUNT PAID BY YOU FOR...

Отзывы: