N100
plus
Inverter RS485 Interface Instruction Manual
2.4
RUN command parameter
2.4.1
A prior condition
(1) Communication number :
1
(Inverter address 1)
(2) Command
:
06 (Setting
request)
(3) Parameter
:
0002
2.4.2
Example 8 – FWD(Forward) RUN Command
(1) Transmit
Data
Transmit (8Byte)
Com.
Num.
Com-
mand
Parameter
Data
CRC 16
Hi Lo
010600020001E9CA 01 06 00 02 00
01 E9 CA
Data Description
0001 : FWD, 0002 : REV, 0000 : STOP
(2) Response
Data
Response (7Byte)
Com.
Num.
Com-
mand
Parameter
Data
CRC 16
Hi Lo
010600020001E9CA
01 06 00 02 00
01 E9 CA
2.4.3
Example 9 – REV(Reverse) RUN Command
(1) Transmit
Data
Transmit (8Byte)
Com.
Num.
Com-
mand
Parameter
Data
CRC 16
Hi Lo
010600020002A9CB 01 06 00 02 00
02 A9 CB
Data Description
0001 : FWD, 0002 : REV, 0000 : STOP
(2) Response
Data
Response (7Byte)
Com.
Num.
Com-
mand
Parameter
Data
CRC 16
Hi Lo
010600020002A9CB
01 06 00 02 00
02 A9 CB
N100_Inverter RS485 Interface Manual(English).doc