General Safety Guidelines
GRX-5100 Hyundai
3.3 An extension cord should not be used unless absolutely
necessary. Use of an improper extension cord could result
in a risk of fire and electric shock. If an extension cord must
be used, make sure:
a. that the pins on plugs of the extension cord are the
same number, size, and shape as those of the plug
on the GRX-5100 Hyundai;
b. that the extension cord is properly wired and in
good electrical condition;
c. that the wire size is large enough for the AC ampere
rating of GRX-5100 Hyundai as specified in the table.
4. Grounding
4.1 The plugs and receptacles have dedicated grounding
terminals and must be mated with plugs and receptacles
having matching grounding terminals
5. GRX-5100 Hyundai Location
IMPORTANT: The GRX-5100 Hyundai is designed for
indoor use only!.
It is the responsibility of the operator to provide a controlled
environment for the equipment. Work tents are a common
method of protecting equipment in adverse conditions.
The GRX-5100 Hyundai depends upon the surrounding air for
cooling. The free flow of air is important as is the air temperature.
The GRX-5100 Hyundai must be mounted so that air can freely
circulate all around it.
5.1 Do not place combustible materials on or near the GRX-
5100 Hyundai or mount the GRX-5100 Hyundai closer
than 3 inches from any adjacent wall. The GRX-5100
Hyundai must never be mounted next to or above heat
generating equipment.
5.2 Locate the GRX-5100 Hyundai as far away from the battery
as the cables permit.
5.3 Never place the GRX-5100 Hyundai directly above the bat-
tery being charged; gases from the battery will corrode
and damage the GRX-5100 Hyundai.
5.4 Only operate the GRX-5100 Hyundai in a well-ventilated
area that is free of dangerous vapors.
5.5 Store the GRX-5100 Hyundai in safe, dry location.
6. DC Connection Precautions
6.1 All switches should be set in the OFF position and AC cord
should be DISCONNECTED from electrical outlet before you
connect the output cables.
Hazardous voltage.
Can cause death or serious
personal injury.
Setting the switches to “OFF” does not always
disconnect the EV/HEV Battery Service Tool
electrical circuit from the AC power cord.
Recommended minimum AWG* size for extension cords for the GRX-5100 Hyundai
AC input rating amperes
AWG* size of cord
Equal or greater than:
But less than:
Length of cord, feet (m)
25
(7.6)
50
(15.2)
100
(30.5)
150
(45.6)
8
10
18
14
12
10
10
12
16
14
10
8
12
14
16
12
10
8
14
16
16
12
10
8
16
18
14
12
8
8
*American Wire Gauge