5.5.
Replacing hydraulic oil HYLS4000H.
5.5.1.
Replace the Hydraulic oil in the log splitter after
every 150 hours of use. Take following steps to
replace it.
5.5.2.
Make sure all moving parts stops and the log
splitter is unplugged.
5.5.3.
Unscrew Oil Drain Bolt with Dipstick to remove
it.
5.5.4.
Turn the log splitter on the Support Leg side over
a 4 litre capacity container to drain the hydraulic oil
off.
5.5.5.
Turn the log splitter on the motor side.
5.5.6.
Refill fresh hydraulic oil at the volume as per the
hydraulic oil capacity of a particular model
indicated in specifications table.
5.5.7.
Clean the surface of Dipstick on the Oil Drain Bolt
and put it back into the oil tank while keep the log splitter vertically.
5.5.8.
Make sure the level of the refilled oil is just between 2 grooves around the
dipstick.
5.5.9.
Clean the oil drain bolt before thread them back. Make sure they are
tightened to avoid leakage before place the log splitter horizontally.
5.5.10.
Periodically check oil level to ensure it is between 2 grooves around the
Dip-stick. If it is at the lower oil level you MUST refill with oil.
5.6.
Replacing hydraulic oil HYLS7000H.
5.6.1.
Replace the Hydraulic oil in the log splitter
after every 400 hours of use. Take following
steps to replace it.
5.6.2.
Make sure all moving parts stops and the log
splitter is unplugged.
5.6.3.
Unscrew Oil Drain Bolt with Dipstick to
remove it.
5.6.4.
Turn the log splitter on the Support Leg side
over a 4 litre capacity container to drain the
hydraulic oil off.
5.6.5.
Turn the log splitter on the motor side.
5.6.6.
Refill fresh hydraulic oil at the volume as per
the hydraulic oil capacity of a particular model
indicated in specifications table.
5.6.7.
Clean the surface of Dipstick on the Oil Drain
Bolt and put it back into the oil tank while keep the log splitter vertically.
5.6.8.
Make sure the level of the refilled oil is just between 2 grooves around the
dipstick.
5.6.9.
Clean the oil drain bolt before thread them back. Make sure they are
tightened to avoid leakage before place the log splitter horizontally.
5.6.10.
Periodically check oil level to ensure it is between 2 grooves around the
dipstick. If it is at the lower oil level you MUST refill with oil.