5.5.

 

Replacing hydraulic oil HYLS4000H. 

5.5.1.

 

Replace the Hydraulic oil in the log splitter after 

every 150 hours of use. Take following steps to 

replace it. 

5.5.2.

 

Make sure all moving parts stops and the log 

splitter is unplugged. 

5.5.3.

 

Unscrew Oil Drain Bolt with Dipstick to remove 

it. 

5.5.4.

 

Turn the log splitter on the Support Leg side over 

a 4 litre capacity container to drain the hydraulic oil 

off. 

5.5.5.

 

Turn the log splitter on the motor side. 

5.5.6.

 

Refill fresh hydraulic oil at the volume as per the 

hydraulic oil capacity of a particular model 

indicated in specifications table. 

5.5.7.

 

Clean the surface of Dipstick on the Oil Drain Bolt 

and put it back into the oil tank while keep the log splitter vertically. 

5.5.8.

 

Make sure the level of the refilled oil is just between 2 grooves around the 

dipstick. 

5.5.9.

 

Clean the oil drain bolt before thread them back. Make sure they are 

tightened to avoid leakage before place the log splitter horizontally. 

5.5.10.

 

Periodically check oil level to ensure it is between 2 grooves around the 

Dip-stick. If it is at the lower oil level you MUST refill with oil. 

5.6.

 

Replacing hydraulic oil HYLS7000H. 

5.6.1.

 

Replace the Hydraulic oil in the log splitter 

after every 400 hours of use. Take following 

steps to replace it. 

5.6.2.

 

Make sure all moving parts stops and the log 

splitter is unplugged. 

5.6.3.

 

Unscrew Oil Drain Bolt with Dipstick to 

remove it. 

5.6.4.

 

Turn the log splitter on the Support Leg side 

over a 4 litre capacity container to drain the 

hydraulic oil off. 

5.6.5.

 

Turn the log splitter on the motor side. 

5.6.6.

 

Refill fresh hydraulic oil at the volume as per 

the hydraulic oil capacity of a particular model 

indicated in specifications table. 

5.6.7.

 

Clean the surface of Dipstick on the Oil Drain 

Bolt and put it back into the oil tank while keep the log splitter vertically. 

5.6.8.

 

Make sure the level of the refilled oil is just between 2 grooves around the 

dipstick. 

5.6.9.

 

Clean the oil drain bolt before thread them back. Make sure they are 

tightened to avoid leakage before place the log splitter horizontally. 

5.6.10.

 

Periodically check oil level to ensure it is between 2 grooves around the 

dipstick. If it is at the lower oil level you MUST refill with oil. 

Page 14

Содержание HYLS4000H

Страница 1: ...LOG SPLITTER HORIZONTAL 4 7 Ton Models HYLS4000H HYLS7000H User Manual...

Страница 2: ...2 MACHINE SPECIFICSAFETY 5 7 3 PARTSLOCATIONS 8 10 4 SPECIFICATIONS 10 5 OPERATION 11 14 6 TROUBLESHOOTING 14 7 PARTSSCHEDULE 15 16 8 PRODUCTDISPOSAL 17 9 DECLARATIONS ofCONFORMITY 17 10 CONTACT DETA...

Страница 3: ...MUST adhere to their warning s Failure to do so may result in personal injury to yourself or those around you The FOLLOWING safety notes will help avoid or reduce risk of injury ordeath Indicates a ha...

Страница 4: ...s the ability of the hand to feel and regulate temperature causing numbness and heat sensations and may cause nerve damage and circulatory tissuedeath 1 3 2 Not all factors that lead to white finger d...

Страница 5: ...splitter to the work surface if it tends to slip walk orslide 2 3 2 Keep your work area clean and well lighted Cluttered areas invitesinjuries 2 3 3 DO NOT use the log splitter in wet or damp areas o...

Страница 6: ...Keep visitors and children away 2 9 1 The log splitter MUST be always operated by one person only Other people should keep a safe distance from the work area especially when the log splitter is under...

Страница 7: ...eave tool until it has come to a complete stop 2 15 2 Dis connect power 2 15 2 1 You MUST unplug when not in use before making adjustments changing parts cleaning or working on the log splitter 2 15 2...

Страница 8: ...on 3 4 turns to allow for air to flow in out of the oil tank smoothly The air flow through the bleed screw should be detectable adjust screw to suit during the log splitter under normal operation Befo...

Страница 9: ...Stand assembly optional HYLS4000H Unplug unit from the mains supply Remove existing support leg then follow steps 3 4 below Page 9 Support leg...

Страница 10: ...e the log splitter works under pressure no more than 4 tons HYLS4000H 7 tons HYLS7000H The setting was done by qualified mechanic with professional instruments Un authorised resetting will cause the h...

Страница 11: ...ltage over current as well as a residual current device RCD which maximum residual current rated at 30mA The diameter of the log is indicative a small log can be difficult to split when it has knots o...

Страница 12: ...or such extremely hard log rotate it by 90 to see whether it can be split in a different direction In any case if you are not able to split the log this means that its hardness exceeds the capacity of...

Страница 13: ...rce the blade by splitting the log on the upper part This will break the blade or damage the machine 5 3 2 Break log in the direction of its growing grain DO NOT place log across the log splitter for...

Страница 14: ...s between 2 grooves around the Dip stick If it is at the lower oil level you MUST refill withoil 5 6 Replacing hydraulic oil HYLS7000H 5 6 1 Replace the Hydraulic oil in the log splitter after every 4...

Страница 15: ...cutter is blunt Refer to Sharpening Wedge section to sharpen the cutting edge Oil leaks Locate leak s and contact dealer Unauthorized adjustment has been made on Max Pressure Limiting Screw Lower the...

Страница 16: ...7 PARTS SCHEMATIC 7 1 HYLS4000H Page 16...

Страница 17: ...7 2 HYLS7000H Page 17...

Страница 18: ...The following symbol means that you should NOT place items with this symbol on the product into your domestic waste 8 5 Unwanted packaging materials should be sorted and taken to a recycling centre to...

Страница 19: ...genpower co uk 10 5 WEBSITE www hyundaipowerequipment co uk 11 MANUAL UPDATES 11 1 Our manuals are constantly being reviewed and updated However ifshould you find an error omission or something you f...

Страница 20: ...www hyundaipowerequipment co uk Isaac Way London Road Pembroke Dock UNITED KINGDOM SA72 4RW T 44 0 1646 687 880 F 44 0 1646 686 198 E info hyundaipowerequipment co uk...

Отзывы: