Repair - Replace the seals.
- Replace the piston.
- Replace the seal.
Fault
Filtrations of oil from the drains be-
tween head and casing
Cause - O-ring seals of casing are worn out.
Repair - Replace the seals.
Fault
Turning on the burner switch the
boiler does not start
Cause - No fuel.
- Fuel filter is clogged.
- Fuel pump is either blocked or burnt out.
- Damaged thermostat.
- Ignition spark insufficient or totally lacking.
- The space among the electrodes is not
correct.
- Burn out fuse.
Repair - Check the level in the tank and check
whether the rigid suction pipe is clean.
- Replace the line filter.
- Replace it.
- Replace it.
- Contact an authorised service centre.
- Check the positioning.
- Replace it.
Fault
Water is not hot enough
Cause - Poor boiler performance.
- Boiler coil clogged with limestone.
Re-
pair
- Clean burner nozzle filter.
- Clean fuel filter.
- Check diesel pump pressure.
- Descaling.
Fault
Too much smoke from the chimney
Cause - Combustion is not correct.
- Impurities or water in the fuel.
Re-
pair
- Clean fuel filter.
- Clean the boiler.
- Empty the tank and clean it carefully.
- Clean fuel filter as well.
Fault
Insufficient detergent suction
Cause - No detergent in the tank.
- Incrusted injector.
- Either coil or tube or lance are clogged.
Re-
pair
- Fill the detergent tank.
- Clean it.
- Either cleaning or descaling.
EN
19
Содержание HY150HPW-1
Страница 1: ...WARNING read the instructions carefully before use HY150HPW 1 PRESSURE WASHER Instruction Manual ...
Страница 3: ...3 Diesel Detergent ...
Страница 6: ...6 Diesel Diesel 4 4 5 5 fig L 1 1 2 2 3 3 6 6 7 7 ...
Страница 7: ...NO NO min 120 A 3B A min 20 cm min 7 9 inch OK B 7 fig M ...
Страница 8: ...H 2 O WATER DIAGRAM 8 ...
Страница 9: ...LKX_LP_3Ph_220V LKX_XP_1Ph LKX_XP_3Ph 1 Ph NPX XP 1 Ph NPX XP 3 Ph ELECTRIC DIAGRAM 9 ...
Страница 20: ...20 ...
Страница 23: ...cod 7 700 0551 rev 00 03 2020 ...