background image

Repair -  Replace the seals.

-  Replace the piston.

-  Replace the seal.

Fault

Filtrations of oil from the drains be-

tween head and casing

Cause  -  O-ring seals of casing are worn out.
Repair  -  Replace the seals.
Fault

Turning on the burner switch the 

boiler does not start

Cause  -  No fuel.

-  Fuel filter is clogged.

-  Fuel pump is either blocked or burnt out.

-  Damaged thermostat.

-  Ignition spark insufficient or totally lacking.

-  The space among the electrodes is not 

correct.

-  Burn out fuse.

Repair  -  Check the level in the tank and check 

whether the rigid suction pipe is clean.

-  Replace the line filter.

-  Replace it.

-  Replace it.

-  Contact an authorised service centre.

-  Check the positioning.

-  Replace it.

Fault

Water is not hot enough

Cause  -  Poor boiler performance.

-  Boiler coil clogged with limestone.

Re-

pair 

-  Clean burner nozzle filter.

-  Clean fuel filter.

-  Check diesel pump pressure.

-  Descaling.

Fault

Too much smoke from the chimney

Cause  -  Combustion is not correct.

-  Impurities or water in the fuel.

Re-

pair 

-  Clean fuel filter.

-  Clean the boiler.

-  Empty the tank and clean it carefully.

-  Clean fuel filter as well.

Fault

Insufficient detergent suction

Cause  -  No detergent in the tank.

-  Incrusted injector.

-  Either coil or tube or lance are clogged.

Re-

pair 

-  Fill the detergent tank.

-  Clean it.

-  Either cleaning or descaling.

EN

19

Содержание HY150HPW-1

Страница 1: ...WARNING read the instructions carefully before use HY150HPW 1 PRESSURE WASHER Instruction Manual ...

Страница 2: ...fig A Depending on the model there are differences in the scopes of delivery DESCRIPTION OF THE MACHINE ...

Страница 3: ...3 Diesel Detergent ...

Страница 4: ...4 INSTALLATION fig C fig B fig D fig E fig F fig G min 30 l min max 1 MPa optional 5 40 C 1 2 inch 13 mm ...

Страница 5: ...5 5 STARTING UP OPTIONAL OPTIONAL spread pattern fig I pressure pressure 1 2 3 4 fig H spread pattern pencil jet ...

Страница 6: ...6 Diesel Diesel 4 4 5 5 fig L 1 1 2 2 3 3 6 6 7 7 ...

Страница 7: ...NO NO min 120 A 3B A min 20 cm min 7 9 inch OK B 7 fig M ...

Страница 8: ...H 2 O WATER DIAGRAM 8 ...

Страница 9: ...LKX_LP_3Ph_220V LKX_XP_1Ph LKX_XP_3Ph 1 Ph NPX XP 1 Ph NPX XP 3 Ph ELECTRIC DIAGRAM 9 ...

Страница 10: ...ays disconnect the electricity and water supplies on completion of every job 03 WARNING Do not use the machine if a supply cord or important parts of the machine are damaged e g safety devices high pressure hoses trigger gun 04 WARNING This appliance has been designed for use with the detergent provided or the detergent specified by the manufacturer such as a neutral shampoo based on biodegradable...

Страница 11: ...e 18 WARNING Never start the high pressure cleaner without first completely unwinding the high pressure hose 19 WARNING When winding and unwinding the pipe take care not to cause the high pressure cleaner to overturn 20 WARNING Before unwinding or winding the hose switch the machine off and release the pressure in the hose itself switching off 21 WARNING Risk of explosion Do not spray flammable li...

Страница 12: ...upply Open the water supply WARNING symbol machinenotsuitable for connection to the potable water mains The cleaner can only be connected to the wa ter mains if the water mains is separated by a backflow preventer Make sure that the hose is at least Ø 13mm 1 2 inch and that it is rein forced WARNING Water that has flown through backflow preventers is considered to be nonpotable IMPORTANT Only clea...

Страница 13: ...em hasn t to be faced when the ma chine operates outdoor but when it s installed indoor the following recommendations must be followed The chimney path must be always in ascent straight vertical if possible and preferably not exceeding a 5 m lenght The exit of the chimney must be sheltered to avoid the dripping of rain and to allow the exaust flow The chimney section A must be 3 times the outlet c...

Страница 14: ...to place by hand without the aid of tools Connect the water supply hose to the snap connection The hose must have an inside diameter of at least 13 mm 1 2 Connect the high pressure hose to the pump s outlet pipe Press the high pressure hose coupling fully down and then screw into place by hand without the aid of tools Connect the high pressure hose to the gun Turn the water tap fully on The water ...

Страница 15: ...ave the stand by mode active for more than 5 minutes At the end of the operation set the switch to OFF Activate hand spray gun until device is pressure less if fitted Machines equipped with delayed low voltage Total Stop with intelligent switch off When the machine is working by releasing the gun lever after approximately 15 seconds the motor stops automatically to prevent component wear during th...

Страница 16: ...ct the gun from the high pressure line and place its free end in the drum in order to form a closed cir cuit and draw the solution into the machine for at least 10 minutes The delivery end of the line should discharge into a canvas or mesh bag so that the scale removed is not re turned to the circuit Then restore the normal connection and rinse with plenty of cold water This operation should be ca...

Страница 17: ...aning operations to which the operative components may be subjected Repairs under this guarantee include replacement of defective parts exclusive of packing and postage car riage The warranty shall not cover replacement of the machine or extension of the guarantee resulting from a breakdown The manufacturer declines all responsibi lity for damage to persons or property caused by bad installation o...

Страница 18: ...and head Cause The seals are worn out The piston is worn out The O ring of the piston cap is worn out Fault When the main switch is turned on the machine does not start Cause Plug not properly connected Connection panel fuses are burnt out Repair Carefully check the plug and the electric cable Check them and replace them Fault The motor hums but does not start Cause A phase is missing in three pha...

Страница 19: ...n pipe is clean Replace the line filter Replace it Replace it Contact an authorised service centre Check the positioning Replace it Fault Water is not hot enough Cause Poor boiler performance Boiler coil clogged with limestone Re pair Clean burner nozzle filter Clean fuel filter Check diesel pump pressure Descaling Fault Too much smoke from the chimney Cause Combustion is not correct Impurities or...

Страница 20: ...20 ...

Страница 21: ...y m s2 2 2 Arm vibrations A weighted r m s acceleration value to which the operators arms are subjected in m s2 ValuesaccordingtostandardEN 60335 2 79 Water connection 40 C Supplytemp max 30 l min Supplyrate min 1MPa SupplyPressure max 21 Detergent tank capacity ...

Страница 22: ...ns andthestandardsEN Declares under its responsability that the machine GENPOWER LTD Isaac Way Pembroke Dock Pembrokeshire SA72 4RW Technicalbookletat GENPOWER LTD Isaac Way Pembroke Dock Pembrokeshire SA72 4RW 29 10 20 Roland Llewellin Managing Director PRODUCT HOTHIGH PRESSUREWASHER MACHINE MODEL HY150HPW 1 2006 42 EC 2009 127 EC 2014 30 EU 2000 14 EC 2005 88 EC 2011 65 EU 2014 68 EU EN60335 1 E...

Страница 23: ...cod 7 700 0551 rev 00 03 2020 ...

Страница 24: ...embroke Dock UNITED KINGDOM SA72 4RW T 44 0 1646 687 880 F 44 0 1646 686 198 E info hyundaipowerproducts co uk www hyundaipowerproducts co uk Imported Distributed by GENPOWER LTD for The United Kingdom Ireland Licensed by Hyundai Corporation Korea ...

Отзывы: