Page 10
4.6.
Engine protection system.
4.6.1.
The engine protecting system is designed to protect engine from damage because of
lack of oil in the crank case.
4.6.2.
When the engine oil in crank case is lower than the safe level line, the engine
protecting system will stop the engine automatically, even if the engine switch is still in
“run” position.
4.6.3.
This will assist in protecting the engine from lack of oil.
5.
STARTING THE ENGINE
Before starting the engine;
Turn ‘OFF’ the AC switch.
DO NOT connect any electrical appliances to the machine.
5.1.
Turn the fuel tap to ‘ON’ position.
5.2.
Turn the engine switch to ‘RUN’
5.3.
Pull the choke lever to the ‘’CLOSED” position. Not necessary when engine is warm.
5.4.
Turn the start switch to “START” position.
Do not keep the switch in the “START” position for more than 5 seconds,
or the starter may be damaged.
If the engine does not start at the first time, try a re-start after waiting
for a 10 second pause.
If the starter turnover speed degrades after time, it means that you will
need to charge the battery.