background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.5.

 

Air Tank warning. 

 

 

Drain liquid from air tank daily, or after each use, using the drain 
valve located on the bottom of the lower air tank. Failure to properly 
drain liquid from the tank will cause rust from the moisture build-up, 
which weakens the tank and could lead to a violent tank explosion. 
Periodically inspect tanks for unsafe conditions such as corrosion.

 

Never attempt to repair or make modifications to the tank or its attachments. Welding, drilling or 
any other modifications may weaken the tank, which may result in damage from rupture or 
explosion. Never remove or attempt to adjust pressure switch, safety valve or other factory set 
operating pressures.

 

 

1.6.

 

Fire warning. 

 

 

Avoid dangerous environments. Do not use compressor near petrol or 
other flammable materials. Keep work area well lit. Normal sparking 
of a motor or sparks from grinding metal could ignite fumes. Do not 
spary flammable materials in the vicinity of an open flame or other 
ignition source, including the air compressor itself. Do not direct paint 
or other spray material towards compressor.

 

Read and follow all safety instructions for the material you are spraying. Be sure to use an 
approved respirator designed for use with your specific application.

 

 

1.7.

 

Breathable air warning. 

 

 

This compressor is not designed, nor intended for the supply of 
breathable quality air. Air produced by this unit may contain carbon 
monoxide or other toxic vapours. Carbon monoxide is colourless and 
odourless, inhaling this gas can cause death as well as serious long 
term health problems such as brain damage.

 

Do not inhale air from the compressor or from a breathing device connected to it.

 

 

1.8.

 

Electric shock warning. 

 

 

When using electric powered tools, machines or equipment, basic 
safety precautions should always be followed to minimise the risk of 
electric shock or personal injury to yourself and others. We 
recommend the use to Residual Current Device to protect the user/s 
against electric shock.

 

This air compressor is powered by electricity and should never be used without proper earth 
connections. Do not use in the wet or damp locations or expose unit to rain.

 

Page 6

Ver 2

Содержание HY0808

Страница 1: ......

Страница 2: ...CATION NUMBERS 3 1 SAFETY 4 8 2 BOX CONTENTS ASSEMBLY PARTS 9 3 INSTALLATION EARTHING 10 4 MAINTENANCE 11 12 5 STORAGE 12 6 TROUBLESHOOTING 12 13 7 SPECIFICATIONS 13 8 ENVIRONMENTAL 14 9 GENPOWER CONT...

Страница 3: ...7880 Service Option 2 Please have ready the Product Model and serial numbers Please make a note of the following details Date of Purchase Dealers Name Dealers Phone number Model Number Serial Number E...

Страница 4: ...en pets livestock and property 1 2 Some or all of the following PPE Warning Signs and symbols may appear throughout this manual and you must adhere to their warning s Failure to do so may result in pe...

Страница 5: ...e following safety precautions must be observed at all times 1 4 2 1 Read all manuals included with this product Be thoroughly familiar with the controls and proper use of equipment 1 4 2 2 Follow all...

Страница 6: ...ncluding the air compressor itself Do not direct paint or other spray material towards compressor Read and follow all safety instructions for the material you are spraying Be sure to use an approved r...

Страница 7: ...sor Air compressors generate significant heat during normal operation which can cause serious burns The compressor will remain hot for some time after operation and should not be touched or moved unti...

Страница 8: ...aning with solvents or toxic chemicals follow the instructions provided by the chemical manufacturer 1 14 Hose precautions 1 14 1 Inspect hose s before use Do not exceed working pressure marked on hos...

Страница 9: ...lter 2 2 Assembly 2 2 1 Attach the air filter to the top right side of motor head 2 2 2 Screw air filter into the motor head 2 3 Parts 1 Tank Drain 6 Pressure Gauge s 2 Air Tank 7 Pump Head 3 Safety R...

Страница 10: ...ect user s against electric shock 3 3 Extension Leads 3 3 1 We do not recommend the use of an electrical extension lead with this product as this may result in loss of power and overheating of the mot...

Страница 11: ...ill become clogged This will reduce the air intake capabilities of the air compressor reducing performance therefore the air filter must be replaced regularly 4 2 3 Open the lid on the air filter then...

Страница 12: ...aks when the compressor is idle Non return valve seal defective Let the air in the tank flow out until all pressure is released Then remove the no return valve plug and clean the valve seal If necessa...

Страница 13: ...ECIFICATIONS Model HY0808 HY0816 Voltage V 230 230 Number of phases 1 1 Frequency Hz 50 50 Connection method Cable length m 3 pin plug BS1363A 1 4 3 pin plug BS1363A 1 4 Motor power hp kw 0 75 0 56 0...

Страница 14: ...8 2 For further information on the disposal of this product please contact your dealer or your nearest domestic waste collection service 8 3 Reduce Reuse Recycle unwanted materials instead of disposi...

Страница 15: ...dai product conform to the following CE Directives 10 1 1 2002 95 EC Restriction of Hazardous Substances 10 1 2 2004 108 EC EMC Directive 10 1 3 2006 42 EC MachineryDirective 10 1 4 2006 95 EC Low Vol...

Страница 16: ...www hyundaipowerequipment co uk GENPOWER LTD Isaac Way London Road Pembroke Dock UNITED KINGDOM SA72 4RW T 44 0 1646 687 880 F 44 0 1646 686 198 info hyundaipowerequipment co uk...

Отзывы: