4.

 

MAINTENANCE 

 

4.1.

 

Draining Air Tank. 

4.1.1.

 

The frequency at which you should drain the air tank depends on the environmental 

conditions and the amount of operating time logged. 

4.1.2.

 

The average draining frequency is every two/three days. 

4.1.3.

 

Place the air compressor above a container capable of holding water. 

4.1.4.

 

With compressed air in air tank, slowly turn the drain valve knob anti-clockwise. The 

water in the air tank will drain out. 

4.1.5.

 

After all of the accumulated water has drained out, turn the drain valve knob 

clockwise until it is tight, this will avoid leakage. 

 

4.2.

 

Changing the air filter. 

4.2.1.

 

The air filter is designed to reduce noise and help dust particles form entering and 

damaging the air compressor. 

4.2.2.

 

After being used for a period of time, the air filter will become clogged. This will 

reduce the air intake capabilities of the air compressor, reducing performance, 
therefore the air filter must be replaced regularly. 

4.2.3.

 

Open the lid on the air filter, then remove old filter. 

4.2.4.

 

Replace it with a new filter, then close the lid. 

 

4.3.

 

Testing for leaks. 

4.3.1.

 

Make sure all connections are tight but be careful not to overtighten. 

4.3.2.

 

A small leak in any hose or pipe connection will reduce the air compressors 

performance. 

4.3.3.

 

To test for small leaks spray a small amount of soapy water on suspected area of 

leakage. If soap solution bubbles, tighten or replace part/s. 

 

4.4.

 

Cleaning. 

4.4.1.

 

Clean items with a soft brush, or wipe with a moistened cloth using a biodegradable 

cleaner. 

4.4.2.

 

Do not use flammable liquids such as petrol or alcohol. Always keep parts clean from 

dirt and dust for a better performance. 

 

4.5.

 

Adjusting the pressure switch. 

4.5.1.1. 

The pressure switch should only be adjusted by suitably qualified persons. 

Page 11

Ver 2

Содержание HY0808

Страница 1: ......

Страница 2: ...CATION NUMBERS 3 1 SAFETY 4 8 2 BOX CONTENTS ASSEMBLY PARTS 9 3 INSTALLATION EARTHING 10 4 MAINTENANCE 11 12 5 STORAGE 12 6 TROUBLESHOOTING 12 13 7 SPECIFICATIONS 13 8 ENVIRONMENTAL 14 9 GENPOWER CONT...

Страница 3: ...7880 Service Option 2 Please have ready the Product Model and serial numbers Please make a note of the following details Date of Purchase Dealers Name Dealers Phone number Model Number Serial Number E...

Страница 4: ...en pets livestock and property 1 2 Some or all of the following PPE Warning Signs and symbols may appear throughout this manual and you must adhere to their warning s Failure to do so may result in pe...

Страница 5: ...e following safety precautions must be observed at all times 1 4 2 1 Read all manuals included with this product Be thoroughly familiar with the controls and proper use of equipment 1 4 2 2 Follow all...

Страница 6: ...ncluding the air compressor itself Do not direct paint or other spray material towards compressor Read and follow all safety instructions for the material you are spraying Be sure to use an approved r...

Страница 7: ...sor Air compressors generate significant heat during normal operation which can cause serious burns The compressor will remain hot for some time after operation and should not be touched or moved unti...

Страница 8: ...aning with solvents or toxic chemicals follow the instructions provided by the chemical manufacturer 1 14 Hose precautions 1 14 1 Inspect hose s before use Do not exceed working pressure marked on hos...

Страница 9: ...lter 2 2 Assembly 2 2 1 Attach the air filter to the top right side of motor head 2 2 2 Screw air filter into the motor head 2 3 Parts 1 Tank Drain 6 Pressure Gauge s 2 Air Tank 7 Pump Head 3 Safety R...

Страница 10: ...ect user s against electric shock 3 3 Extension Leads 3 3 1 We do not recommend the use of an electrical extension lead with this product as this may result in loss of power and overheating of the mot...

Страница 11: ...ill become clogged This will reduce the air intake capabilities of the air compressor reducing performance therefore the air filter must be replaced regularly 4 2 3 Open the lid on the air filter then...

Страница 12: ...aks when the compressor is idle Non return valve seal defective Let the air in the tank flow out until all pressure is released Then remove the no return valve plug and clean the valve seal If necessa...

Страница 13: ...ECIFICATIONS Model HY0808 HY0816 Voltage V 230 230 Number of phases 1 1 Frequency Hz 50 50 Connection method Cable length m 3 pin plug BS1363A 1 4 3 pin plug BS1363A 1 4 Motor power hp kw 0 75 0 56 0...

Страница 14: ...8 2 For further information on the disposal of this product please contact your dealer or your nearest domestic waste collection service 8 3 Reduce Reuse Recycle unwanted materials instead of disposi...

Страница 15: ...dai product conform to the following CE Directives 10 1 1 2002 95 EC Restriction of Hazardous Substances 10 1 2 2004 108 EC EMC Directive 10 1 3 2006 42 EC MachineryDirective 10 1 4 2006 95 EC Low Vol...

Страница 16: ...www hyundaipowerequipment co uk GENPOWER LTD Isaac Way London Road Pembroke Dock UNITED KINGDOM SA72 4RW T 44 0 1646 687 880 F 44 0 1646 686 198 info hyundaipowerequipment co uk...

Отзывы: