The compressor
does not reach
maximum
pressure.
Compressor head gasket
broken of faulty valve.
Stop the compressor and contact your dealer.
Compressor
doesn’t seem to
provide as much
air it did when
new and/or the
compressor cuts
off within a much
shorter time
period.
The pressure switch
needs adjusting.
Stop the compressor and contact your dealer.
The tank is full of water
due to condensation.
Open the ball valve and release the pressure.
Open the drain valve and release the water within the
tank.
The motor pump
unit does not
stop when the
tank pressure
reaches its
maximum
working pressure
(8 Bar/116PSi)
and the safety
valve vents air
Pressure switch defective
or needs adjusting.
Stop the compressor immediately and contact your
dealer.
7.
SPECIFICATIONS
Model
HY0808
HY0816
Voltage - V
230
230
Number of phases
1
1
Frequency – Hz
50
50
Connection method/Cable length m
3 pin plug - BS1363A/1.4
3 pin plug - BS1363A/1.4
Motor power hp/kw
0.75/0.56
0.75/0.56
Rated Speed (motor) – RPM
1430
1430
Cubic Foot per Minute @ 6.2 Bar
2.4
2.4
Maximum Pressure - PSi/Bar
145/10
145/10
Cut-out Pressure - PSi/Bar
128/8.8
128/8.8
Cut-inPressure - PSi/Bar
87/6
87/6
Tank Capacity - L
8
2 x 8
Free air delivery - CFM - L/min
2.4/68
2.4/68
Displacment - CFM/L/min
3.1/73
3.1/73
Displacement @ 40 psi L/min
55
55
Displacement @ 90 psi L/min
32
32
Air Outlet
Machine - Male 3/8" tapered
quick release euro/Hose -
Male 3/8" euro coupling
Machine - Male 3/8" tapered
quick release euro/Hose -
Male 3/8" euro coupling
Output pressure regulation type
Adjustable
Adjustable
Drive type
Direct
Direct
Overall Unit Dimensions L x W x H mm
490 x 405 x 390
490 x 400 x 530
Net Weight - kg
17.3
23.2
Tank material
Rolled steel
Rolled steel