General Specifications
HYUNDAI INVERTER
Starting signal
Abnormality reset
Multispeed selection
2nd function selection
Output stop
Current input selection
Self-protection function at starting
External TRIP contact input
External thermal input
Operation mode selection
Voltage/frequency characteristic
Operation functions
Output signals
Displayed on
control panel
LED Display
Frequency
setting
Analog
digital
Operation status
For meter
Error details
Protective and warning functions
International direction
Control
charac-
teristic
Display
function
Input signal
Item
022SF
007SF
015SF
Type
0 to 5VDC, 0 to 10VDC, 4 to 20 mA, External variable resistor (1 k
Ω
~2 k
Ω
,1 W),
main unit volume resistor Input from control panel
Individual selection of forward or reverse run
Used to reset fault output provided when protective function is activated
Maximum 16 speeds (each speed can be set between 0 and 400 Hz), speed can be changed during operation
Acceleration/deceleration time, base frequency, maximum frequency, multistage frequency,
torque boost, electronic thermal, control method, motor parameter
Instant shut-off of inverter output (frequency/voltage)
Input selection of frequency setting current signal
Self-protection selection of start signal
Contact input for when stopping the inverter with external terminal
Thermal contact input for when stopping inverter with externally mounted thermal relay
Control panel or external operation transition selection programmable.
V/f control or sensorless vector control method selection programmable.
Multispeed operation, operation mode selection, DC braking, upper/lower frequency setting,
frequency jump operation, PID control, AVR, 2-stage accel./decel., instantaneous power failure
restart operation, electronic thermal, software lock, carrier frequency adjustment,
auto tuning function, RS485 link operation, starting frequency adjustment, jogging operation,
retry function, automatic torque boost function, usp function.
Inverter running, frequency reach, frequency detection, overload warning fault
Output frequency, output current, output voltage
Fault list, fault history
Power on (POWER), operational state (RUN), PRG, frequency (Hz), output current (A),
RUN terminal, MIN/MAX volume terminal
Overcurrent shut-off, regenerative overvoltage shut-off, undervoltage, output short circuit,
temperature abnormality, overload shut-off (electronic thermal), ground fault protection,
external trip, communication error, USP error, EEPROM error
CE
Model name
N50-007SF
N50-015SF
N50-022SF