Function List
HYUNDAI INVERTER
Function code
Software
lock
(LOCK)
Name
Initial value Minimum value Maximum value
Unit
Code description
b01
b02
b03
b04
b10
b11
b14
b15
b16
b17
b12
b13
b08
b09
b06
b05
0
0
1.0
1.0
100.0
125.0
0.50
5.0
1.00
1
1
1
1.0
0
0
0
0
0
0
0.3
0.3
20.0
20.0
0.50
0.5
0.01
1
0
0
0.1
0
0
0
0
3
3
1.0
3.0
120.0
200.0
10.00
16.0
99.99
1
3
10.0
1
1
2
2
-
-
sec
sec
%
%
Hz
kHz
-
-
-
-
sec
-
-
-
-
0: alarm output after trip
1: restart at 0 Hz
2: resume operation after frequency matching
3: resume previous frequency after
frequency matching then decelerate to
stop, trip after stop
overcurrent trip, restart up to 3 times,
overvoltage trip, restart up to 3 times,
undervoltage trip, restart up to 10 times
0.3~1.0 sec (by 0.1 sec)
0.3~3.0 sec (by 0.1 sec)
0.2X (inverter rated current)~1.2X (inverter rated current)
0.2X (inverter rated current)~2.0X (inverter rated current)
0.50~10.00 Hz (by 0.01 Hz)
0.5~16 kHz (by 0.1 kHz)
0.01~99.99 (by 0.01)
Communication number setting is 1 to 32
0: stop enabled
1: stop disabled
Operation setting when the free-run stop is cancelled
0: 0 Hz restart
1: frequency matching restart
2: free run stop
0: Trip history initialization
1: Data initialization
0: Korea version
1: Europe version
2: US version
0: SUB (reduced torque characteristic)
1: CRT (constant torque characteristic)
0: overload, overvoltage restriction mode OFF
1: overload restriction mode ON
2: overvoltage restriction mode ON
3: overload, overvoltage restriction mode ON
Deceleration rate when inverter restricts overload
0.1~10.0 sec (by 0.1 sec
)
0: All parameters are locked when SFT
from terminal is on.
1: All parameters except frequency setting
are locked when SFT from terminal is on.
2: All parameters are locked
3: All parameters except frequency setting are locked.
Selection of restart mode
after instantaneous failure
Allowable instantaneous
power failure time setting
Reclosing stand by after instantan-
eous power failure recovered
Electronic thermal level setting
Electronic thermal
characteristic selection
Overload restriction
mode selectio
n
Overload restriction level setting
Start frequency adjustment
Carrier frequency adjustment
Overload restriction
constant setting
Initialization mode selection
Stop key validity selection
during terminal operation
Restarting after free-run
stop signal selection
Initial value selection
(country code)
Software lock selection
Frequency conversion value setting
Communication number
b07
Instan-
taneous
power
failure
restart
Electronic
thermal
Overload
restriction
Others
32
Expanded Function b Mode
Содержание HiRun N50 Series