5.1.6.
To reset the breaker do the following;
5.1.6.1.
Turn OFF and disconnect all loads.
5.1.6.2.
Reset breaker, and add load onto the circuit to within 50% to 75% of rated
output.
5.1.7.
Wait a few minutes before resuming operation.
5.2.
Electrical appliances, particularly motor driven equipment, will have a very high start-up
current. The table below provides reference for connecting these appliances to the
generator.
Type
Wattage
Typical
appliance
Example
Starting
Rated
Appliance
Starting
Rated
Lighting
x 1
x 1
Incandescent
lamp or heating
appliance
Incandescent
lamp 1000
watts
100 vA
100 vA
Heating
Appliance
Fluorescent
Lamp
x 2
x 1 to x 1.5
Fluorescent
Lamp
Fluorescent Lamp
80 vA
40 to 60
vA
Motor
Driven
Equipment
x 3.5
x 1 to 2
Refrigerator,
Electric fan,
Compressor or
grinder
Refrigerator 150
watts
450 to 750
vA
150 to 30
vA
6. STOPPING MACHINE
•
Do not stop the engine suddenly or whilst under load.
•
This can damage the AVR and cause damage to the alternator through
overheating.
•
Do not stop the engine with the decompression lever.
6.1.
Switch OFF equipment connected to the generator.
6.2.
Turn off the main breaker switch.
6.3.
Run the generator without load for three minutes.
6.4.
Turn the electric key start switch to the 'OFF'
position.
6.5.
Or press or pull down the stop lever.
Page 19
Rev 3
Содержание DHY6000LR
Страница 2: ...Page 2 Rev 3 ...
Страница 11: ...2 MACHINELAYOUT Page 11 Rev 3 ...
Страница 23: ...11 WIRINGDIAGRAM 11 1 N B Subject to change without prior notice Page 23 Rev 3 ...
Страница 25: ...12 SERVICE RECORD SHEET Date Hours Maintenanceundertaken Name Page 25 Rev 3 ...
Страница 29: ...NOTES Page 29 Rev 3 ...
Страница 30: ...NOTES Page 30 Rev 3 ...
Страница 31: ...NOTES Page 31 Rev 3 ...