14
5.7
This will decrease priming time and improve pump performance by increasing the
discharge head.
5.8
Suction head is a maximum of 25 feet and discharge head should be a maximum of 81
feet.
5.9
Total head cannot be more than 106 feet.
Pump Positioning
5.10
For best pump performance, locate the pump on a flat, level surface as close as
possible (but avoiding soft edges) to the water to be pumped.
5.11
Secure the water pump to prevent it from tipping over.
5.12
Use hoses that are no longer than necessary.
NOTE
Direct the open end of the discharge hose away from property, electrical supply sources
and any other equipment that you do not want to get wet.
5.13
This water pump is not for use in mobile equipment or marine applications.
5.14
DO NOT top the engine or equipment at an angle that may cause the fuel to spill.
5.15
Secure the water pump, loads from hoses may cause the machine to tip over.
Priming the Pump
NOTE
The improper treatment of the water pump can cause damage and shorten the pumps
lifespan.
5.16
Be sure the priming chamber has been filled with water before starting
NEVER
run the pump without priming.
Suction
Head
Total
Head
Discharge
Head