User manual 

15 

 

control/measure/monitor

 

generator

 

set

 

through

 

computer.

 

The

 

AMF20/25

 

panel

 

has

 

a

 

LCD

 

to

 

display

 

generator

 

set

 

parameters,

 

and

 

has

 

OFF/MAN/AUTO/MEASUREMENT

 

mode.

 

 

Introduction

 

of

 

pushbutton

 

and

 

LED

 

in

 

the

 

AMF20/25

 

control

 

panel

 

1.

 

Start

up

     

Start

 

the

 

engine.

 

2.

 

Stop

           

Stop

 

the

 

engine.

 

3.

 

Reset

         

Clean

 

failure

 

and

 

alarm

 

state.

 

4.

 

Horn

 

reset

       

Deactivates

 

the

 

horn

 

5.

 

Mode

 

left

   

Change

 

the

 

generator

 

set

 

mode.

 

left

handed(MEASUREMENT

AUTO

MAN

OFF)

 

6.

 

Mode

 

right

   

Change

 

the

 

generator

 

set

 

mode

 

left

handed.

 

(OFF

MAN

AUTO

MEASUREMENT)

 

7.

 

Generator

 

set

 

power

 

on/off

 

 

Manual

 

generator

 

set

 

power

 

switch.

 

8.

 

Mains

 

power

 

on/off

 

 

Manual

 

mains

 

power

 

switch.

 

9.

 

Generator

 

set

 

power

 

fault

 

Red

 

LED

 

flash,

 

generator

 

set

 

power

 

fault.

 

After

 

press

 

reset

 

pushbutton,

 

red

 

LED

 

light

 

(still

 

fault

 

and

 

alarm)

 

or

 

no

 

(no

 

alarm).

 

10.

 

Generator

 

set

 

power

 

in

 

gear

 

Green

 

LED

 

light.

 

11.

 

Connect

 

generator

 

set

 

power

 

present

 

 

Green

 

LED

 

light,

 

generator

 

set

 

output

 

switch

 

is

 

on,

 

otherwise

 

the

 

green

 

LED

 

flash.

 

12.

 

Connect

 

mains

 

power

 

present

 

 

Green

 

LED

 

light,

 

mains

 

power

 

switch

 

is

 

on,

 

otherwise

 

the

 

green

 

LED

 

flash.

 

13.

 

Mains

 

power

 

in

 

gear

 

 

Green

 

LED

 

light

 

means

 

mains

 

power

 

is

 

in

 

gear

 

and

 

has

 

the

 

right

 

voltage.

 

14.

 

No

 

mains

 

power

   

Red

 

LED

 

flash

 

means

 

no

 

mains

 

power

 

and

 

generator

 

set

 

is

 

not

 

running;

 

red

 

LED

 

light,

 

means

 

generator

 

set

 

is

 

running

 

and

 

mains

 

power

 

is

 

active

 

but

 

not

 

connect.

 

15.

 

LEDS

 

present

 

16.

 

Page

 

 

Display

 

menu

 

(calculate

set

history).

 

17.

 

Up

   

Page

 

up

 

selection,

 

select

 

screen

 

or

 

add

 

set

 

value.

 

18.

 

Down

 

Page

 

down

 

selection,

 

select

 

screen

 

or

 

minish

 

set

 

value.

 

19.

 

Enter

 

 

Confirm

 

selection.

 

 
 
 

Check

 

parameter

 

A.

 

Press

 

page

 

push

 

button

 

several

 

times

 

to

 

select

 

MEASUREMENT

 

menu

 

B.

 

Use

 

UP/DOWN

 

pushbutton

 

to

 

check

 

the

 

detail

 

Operation

 

and

 

application

 

When

 

the

 

power

 

supply

 

LED

 

is

 

light

 

means

 

AMF

 

controller

 

is

 

active,

 

then

 

user

 

can

 

select

 

operation

 

type

 

(OFF/MAN/AUTO/MEASUREMENT)

 

A.

 

OFF

 

mode

 

Start;

 

stop;

 

mains

 

power

 

on/off;

 

generator

 

set

 

power

 

on/off

 

is

 

inactive

 

in

 

this

 

mode

 

B.

 

MAN

 

mode

 

1.

 

Press

 

start

 

pushbutton

 

to

 

start

 

engine

 

2.

 

When

 

output

 

voltage

 

is

 

in

 

the

 

set

 

range

 

       

a.

 

Press

 

mains

 

power

 

on/off

 

pushbutton

 

to

 

turn

 

on

 

the

 

switch

 

   

b.

 

Press

 

mains

 

power

 

on/off

 

pushbutton,

 

the

 

switch

 

will

 

be

 

turned

 

on,

 

otherwise

 

not

 

if

 

the

 

output

 

voltage

 

is

 

not

 

in

 

gear

 

3.

 

Press

 

generator

 

set

 

power

 

on/off

 

pushbutton

 

to

 

turn

 

on

 

the

 

switch

 

4.

 

Press

 

mains

 

power

 

on/off

 

pushbutton,

 

the

 

switch

 

will

 

be

 

turned

 

on,

 

otherwise

 

not

 

if

 

the

 

mains

 

power

 

voltage

 

is

 

not

 

in

 

gear.

 

5.

 

Press

 

stop

 

pushbutton

 

for

 

a

 

while

 

to

 

stop

 

engine

 

C.

 

AUTO

 

mode

 

1.

 

When

 

mains

 

power

 

is

 

confirmed

 

       

a.

 

Controller

 

turns

 

on

 

the

 

mains

 

power

 

switch

 

   

b.

 

Controller

 

start

 

engine

 

after

 

emergency

 

starting

up

 

delay

 

   

c.

 

If

 

mains

 

power

 

comes

 

back

 

during

 

the

 

start

up

 

period,

 

controller

 

will

 

turn

 

off

 

the

 

mains

 

power

 

switch

 

and

 

stop

 

engine

 

after

 

switch

 

delay

 

2.

 

After

 

engine

 

rotate

 

speed

 

is

 

higher

 

than

 

the

 

lowest

 

set

 

value

 

in

 

maximal

 

delay,

 

controller

 

will

 

turn

 

on

 

the

 

generator

 

set

 

power

 

switch,

 

otherwise

 

controller

 

will

 

alarm

 

and

 

stop

 

engine

 

3.

 

After

 

mains

 

power

 

come

 

back

 

 

     

a.

 

Controller

 

will

 

turn

 

on

 

the

 

generator

 

set

 

power

 

switch

 

after

 

the

 

mains

 

power

 

comeback

 

delay

 

       

b.

 

Controller

 

will

 

turn

 

on

 

the

 

mains

 

power

 

switch

 

after

 

the

 

generator

 

set

 

power

 

delay.

 

       

c.

 

Cool

down

 

and

 

stop

 

the

 

engine

 

D.

 

Alarm

 

User

 

can

 

activate

 

alarm

 

list

 

in

 

the

 

last

 

display

 

of

 

MEASUREMENT

 

menu,

 

Select

 

MEASUREMENT

 

menu,

 

press

 

UP

 

button,

 

you

 

will

 

see

 

all

 

active

 

alarm

 

number

 

in

 

the

 

left

 

upper

 

LCD.

 

All

 

active

 

alarm

 

is

 

in

 

shadow

 

otherwise

 

is

 

not,

 

and

 

also

 

not

 

confirmed.

 

Press

 

reset

 

button

 

to

 

confirm

 

all

 

alarm,

 

all

 

inactive

 

alarm

 

will

 

be

 

canceled

 

at

 

once,

 

If

 

a

 

new

 

alarm

 

happens,

 

this

 

active

 

alarm

 

will

 

be

 

display

 

in

 

LCD

 

and

 

is

 

active

 

state

 

in

 

main

 

measurement

 

screen.

 

 

P10/16

 

control

 

system

 

module

 

introduction

 

Содержание DHY11KSE

Страница 1: ...Diesel Generator User Manual...

Страница 2: ......

Страница 3: ...s close to the battery and fuel because the mixture of volatilization from fuel and hydrogen generated by battery charging process will cause explosion when it meets sparkle or naked flame The generat...

Страница 4: ...is running do not attempt to reach under or around the guards to do maintenance or for any other reason Keep hands arms long hair loose clothing and jewelers away from pulleys belts and other moving...

Страница 5: ...al disconnected prior to attempting to connect or disconnect load connections Do not attempt to connect or disconnect load connections while standing in water or on wet or soggy ground Make sure conne...

Страница 6: ...rator Set Working Room 4 2 5 Installation of Generator Set 5 2 6 Cooling system 7 2 7 Lubricant system 8 2 8 Fuel system 8 2 9 Battery 10 2 10 Electrical Connection 11 2 11 Power distribution system 1...

Страница 7: ...andby power supply to provide continue electric power for non invariable loads The generator set is suitable for the area where must ensure continue power supply such as hospitals industrial facilitie...

Страница 8: ...pusher fan and thermostat The alternator has its own internal fan to cool the alternator components 1 6 Electrical System The engine electrical system is 12 volt or 24 volts DC negative ground earth...

Страница 9: ...litated onnect direc valve is an UNDAI Pow n for the rplus lubrica t by openin ransportatio been designe Standard ca fting hole o enerator set canopy roo me which b o have stati the generato Optional...

Страница 10: ...ect to other architecture s foundation The width and depth of foundation shall meet requirement Ensure foundation s levelness and smoothness If possible waste discharge sink can be sued so that the wa...

Страница 11: ...et to outside For example corrugated vibration reduction pipe has been used to connect exhaust pipes air exhaust path fuel inlet pipe fuel return pipe and busbar cable etc all of these parts need to u...

Страница 12: ...ssure and side stress Reserve some space for hot shrinkage and cold expansion Reserve space for generator set vibration Reduce exhaust noise level Overload of exhaust backpressure will cause following...

Страница 13: ...the liquids in a separate container evenly and then add the mixture into the radiator ensure the anti freeze will not freeze under low temperature In the area when there is low possibility of freezing...

Страница 14: ...specification as that existing in the radiator For some generator sets installed with coolant filter please open the filter s valve before put into use 2 7 Lubricant system Lubricant system is compose...

Страница 15: ...or sets provide base frame style fuel tank for customer The base frame style fuel tank is installed with fuel tank fuel pipes and fuel level indicator This fuel supply system does not need customer to...

Страница 16: ...are required to correctly connect the signal line to this control panel details see the control panel operation manual Automatic transfer panel optional is the automatic transfer switch for transfer...

Страница 17: ...t be connected to an earth ground Since the set is mounted on vibration isolators the ground connection must be flexible to avoid possible breakage due to vibration Ground connection cables or straps...

Страница 18: ...tart Part of the generator set control panel has been furnished with idle speed full speed transfer switch users can choose if the engine need to be started in idle speed or in one time full speed Usu...

Страница 19: ...ing situation and if there is any malfunction warning generator set shut down etc Only when the correct and complete record for running maintenance has been kept very well the user can get correct and...

Страница 20: ...number 3 times the Alarm LCD would flash If you need to restart wait at least 30 seconds before the retry 8 Check the reading of Voltage Meter and Frequency Meter by operating the Voltmeter Change Ov...

Страница 21: ...ight means AMF controller is active then user can select operation type OFF MAN AUTO MEASUREMENT A OFF mode Start stop mains power on off generator set power on off is inactive in this mode B MAN mode...

Страница 22: ...if generator set is used for self start standby power In order to achieve full automatic transfer between mains power and generator set power to guarantee all load present our ATS panel select the bes...

Страница 23: ...O that is OK detail operate step refer module control system ATS PANEL introduction No MODEL 1 ATS switch 2 panel lock 3 mains power output hole 4 generator power output hole 5 communicate with genera...

Страница 24: ...battery For each 50 600 hours of running or at least each 12 months Change lubricant and lubricant filter Because the quality of lubricant oil sulfur content of the fuel and lubricant consumption rate...

Страница 25: ...refer to Control Panel Operation Manual for details 4 5 Start battery Batteries which have been stored in a long time shall be properly charged before being used so that to ensure normal capacitance o...

Страница 26: ...iminate the malfunction s Especially important for new generator set s customer One thing must to be emphasized most of the malfunctions are caused by user s improper installation operation and mainte...

Страница 27: ......

Страница 28: ......

Страница 29: ......

Страница 30: ......

Страница 31: ......

Страница 32: ......

Страница 33: ......

Страница 34: ......

Страница 35: ...DHY10KE KSE DHY250KE KSE...

Страница 36: ...DHY10KE KSE DHY250KE KSE...

Страница 37: ...DHY10KE KSE DHY250KE KSE...

Страница 38: ...DHY10KE KSE DHY250KE KSE...

Страница 39: ...DHY10KE KSE DHY250KE KSE...

Страница 40: ...DHY10KE KSE DHY250KE KSE...

Страница 41: ...APPENDIX E 1...

Страница 42: ...2...

Страница 43: ...3...

Страница 44: ...running record TIME ENGINE PARAMETER GENERATOR PARAMETER IF RECORD FOR MALFUNCTION IS AVAILABLE OPERATOR REMARK Start stop generator set time Accumulated running time Oil pressure Temperature Voltage...

Страница 45: ...serial No Engine serial No Alternator serial No Accumulated running hours Maintenance cycle Reasons for maintenance periodic maintenance or malfunction maintenance Inspection and repair Inspection an...

Страница 46: ...APPENDIX H...

Страница 47: ......

Страница 48: ...Licensed by Hyundai Corporation Korea For Inquiries Please Contact GRV POWER PRODUCTS S L Avda Alguema 8A 17771 Sta LLogaia Alguema Spain Tf 34 972 67 38 36 www hyundaipower es...

Отзывы: