background image

Precautions 

4

5

Please read the precautions thoroughly for your safety! 

•   

The digital product is assembled minutely and complicatedly 
in the inside. 

•  

 The random dismantlement may be dangerous  
besides making the troubles of the product. 

•  

Consumer’s responsibility in case of random dismantlement .

You should not dismantle randomly  

the product 

DANGEROUS 

•   

It’s prohibited to clean with water because water cleaning 
may disturb an electronic circuit. 

•  

It’s hoped that a dry towel is used for cleaning the product. 

Prohibition of water cleaning 

CAUTIONS

•   

The usage period of battery is at most four months to eight 
months.  (Based on the use of ten times a day)  
Exchange the battery at that time. 

•   

Use 4 alkaline batteries of 1.5v AA.  
(Rechargeable batteries unusable) 

•    

In case of full discharge, it’s possible to open the door with 

fingerprint, touch-key and password with linking 9V alkaline 

battery to outdoor body terminal.

The response measures to electric  

discharge of battery are as follows 

WARNING

1. Password registration method 

2. Card registration method

 

  Open the battery cover on the indoor unit of the door lock (the indoor unit) with the door open,  

and press the registration button

  

① 

on the left bottom side.

 

 

Enter the numbers you want on the number panel of the front unit. (3-12 digit numbers possible)

  

When you press 

“ ”

 a notification sound (sounding”ppiririk”) will be heard and register next passwords 

 

in order(Max 5.)

For your safety, we recommend you to use all RF-card and Tag that manufacturer provide with. 
HYUNDAI TELECOM confirms that “ISO 14443 Type A”certified RF-card and Tag to be used with 
the Digital door locks. We, HYUNDAI TELECOM, are not responsible with the cases that  
customers use other type RF-card and Tag, credit card, Smart card and Mobile phone.

 

  Open the battery cover on the indoor unit of the door lock (the indoor unit) with the door open,  

and press the registration button

 

② 

on the right bottom side. 

  

On the screen, the numbers 1, 2, 3, 7, 8, 9 are lit.  

(If transmission module isn’t connected, only 1, 3, 7, 8, 9 are lit)         

  

Press “1” - the numbers are blink on the screen. 

 Hold the card near the reader. (continuous registration possible), (Max. 50 cards) 

  Press the registration button 

② 

on the indoor unit. (the card registration finished)

 

After card registration, make sure it works. 

WARNING

How to use 

After password registration, make sure it works 

1.  When you register passwords for the first time or change them, the door may be locked  

by mistake. Make sure to open the front door and carry an emergency key, card, with you.

2. For the passwords, specify the 3-12 digit numbers except for 

“ ”

 and “#” 

3. If you enter new passwords, the existing ones will be deleted. 
4. When all products are delivered, their passwords are set into 1, 2, 3, 4 and 1, 2, 3, 4, 5, 6, 7, 8, 9, 0. 
5.  When you install a product for first time, make sure the user enters the passwords himself/herself.

CAUTION

Using the Mechanical key

The mechanical key is used when the lock does not operate  

due to discharged batteries or a circuit problem.
Insert the key into the keyhole and rotate it to the right or left to lock  

to unlock the lock.

1. Always carry one or more mechanical keys, or store one in a secret place outside.
2.  If the mechanical key is lost, it is recommended to replace the whole key cylinder unit.  

Contact your local dealer. Replacement of the key cylinder unit is not a free service.

3.  Remove the mechanical key from the keyhole  

after the lock has been released, and store it in a safe place.

CAUTION

1-1. One time password registration method

 

 Press the Start button for 3 sec with the door close, and the number pad will be lit.

 

Enter the current password and “

”.     

  

Enter the one time password and “

”.

  

After you use the one time password, this password will be deleted.

Содержание HDL-7300SK

Страница 1: ...in emergency case When the lock does not operate due to discharged batteries or a circuit problem you can use the mechanical key Self diagnosis function The door lock itself diagnoses defect and info...

Страница 2: ...d RF Card 9V Emergency Start Button Start Button Mechanical key 9V Emergency Mechanical key Battery cover Close Button Handle General Information 3 Precautions 4 How to use 5 Product specification 12...

Страница 3: ...thebatterycoverontheindoorunitofthedoorlock theindoorunit withthedooropen andpresstheregistrationbutton ontherightbottomside Onthescreen thenumbers1 2 3 7 8 9arelit Iftransmissionmoduleisn tconnected...

Страница 4: ...s theft or hacking Also this model uses a semiconductor method sensor so it is safe due to no residual fingerprint left on the sensor unit When you register your fingerprint you must register it four...

Страница 5: ...imes warning alarm is notified and external button stops for 30 seconds 8 Waytolockthedoormanually 11 Waytoopenthedoor With releasing Auto door close function door does not close automatically and fol...

Страница 6: ...ntheindoorunit theremotecontrollerregistrationfinished You can register up to 3 remote controllers If you add one you have to delete and register all in order 14 Waytodeletealltheremotecontrollers Com...

Страница 7: ...oor you have to enter the password Card or Password Fingerprint Double Checking to Register Press the CLOSE button for 3 sec and Press 7 button To register new password card press left right register...

Страница 8: ...epair for Cost In case the same troubles occur three times Product replacement Repair for Cost In case there is no any parts for repair Product replacement Product replacement Limited to flat rate dep...