23
result in poor transmitting performance, and even damage to the transmitter.
2. Check if connection between the transmitter and RF or antenna cables is loose or lost.
If yes, please secure the connection or replace the cables.
3. If you cannot solve the issue, please contact your local dealer for technical support.
When the VSWR falls within the normal range, the LCD prompt will disappear, and the
Alarm Indicator will go out.
Low Forward Power Alarm
When the forward power is below the preset value, the Alarm Indicator will glow red and
the LCD will display the prompt below:
Then the repeater may continue transmission or may terminate it, subject to repeater
status currently detected.
You will need to:
1. Check if connection between the transmitter and RF or antenna cables is loose or lost.
If yes, please secure the connection or replace the cables.
2. If you cannot solve the issue, please contact your local dealer for technical support.
When the forward power is recovered to its normal value, the LCD prompt will disappear,
and the Alarm Indicator will go out.
Over/Low Voltage Alarm
When voltage is over or below the normal operating range (11V-15.6V) of the repeater, the
Alarm Indicator will glow red and the LCD will display the prompt below: