TC-618/626 Service Manual
82
TX Low Voltage
Threshold
158
SQL Level 1 ON
27
25
27
25
24
18
18
17
17
20
SQL Level 5 ON
21
19
19
18
19
14
13
13
13
14
SQL Level 9 ON
9
9
9
9
9
7
7
7
7
7
SQL Level 1 OFF
39
30
31
32
32
27
26
24
25
26
SQL Level 5 OFF
28
25
25
25
26
21
21
19
17
19
SQL Level 9 OFF
12
11
12
11
13
8
8
8
8
8
RX Low Voltage
Threshold
166
Bandpass Filter
353
401
428
470
500
Appendix 2: Reference Value for TC-618/626 Battery Strength
Test in Tx status:
Green LED glows (70%~100%)
>7.35V
18 Minutes
Orange LED glows (50%~70%)
7.15V - 7.35V
12 Minutes
Red LED glows (30%~50%)
7.00V - 7.15V
12 Minutes
Red LED flashes (<30%)
6.20V - 7.00V
18 Minutes
Red LED f Alarm sounds
5.80V - 6.20V
Power off
<5.80V
Test in Rx/Standby status (or by the battery test button press):
Green LED glows (70%~100%)
>7.55V
18 Minutes
Orange LED glows (50%~70%)
7.35V -7.55V
12 Minutes
Red LED glows (30%~50%)
7.00V - 7.35V
20 Minutes
Red LED flashes (<30%)
6.50V - 7.00V
18 Minutes
Red LED f Alarm sounds
every 10 seconds
5.80V - 6.50V
Содержание TC-618
Страница 1: ......
Страница 84: ...TC 618 626 Service Manual 83 Troubleshooting Flow Chart Transmit Circuit ...
Страница 86: ...TC 618 626 Service Manual 85 MCU ...
Страница 91: ...TC 618 626 Service Manual 90 TC 626 ...
Страница 95: ...TC 618 626 Service Manual 94 Packing TC 618 as the example ...
Страница 96: ......
Страница 97: ......
Страница 98: ......
Страница 99: ......