2200 SRM 1324
Technician Menu
DIAGNOSTICS
NOTE:
Once the Run Diagnostics menu has been se-
lected, you cannot return to the Diagnostics menu.
The only way to exit Run Diagnostics is to cycle the
key switch.
A series of submenus are available from the Diagnos-
tics menu. Within the Diagnostics menu, you can ac-
cess the Fault Log, Controller Inputs, Control Handle
Inputs, and Run Diagnostics. See Table 3. Use the
LH LOWER [#1] and LH LIFT [#2] switches to scroll
between the menu choices. See Figure 11. When the
proper menu item has been highlighted, press the
RH LOWER [#4] switch to move to the selected sub-
menu. Use the RH LIFT [#3] switch to return to the
previous menu.
Table 3. Diagnostics Menu
Diagnostics
Press
→
Key
Fault Log
↑
Scroll
↓
Controller
Inputs
↑
Scroll
↓
Ctrl Hdl
Inputs
↑
Scroll
↓
Run
Diagnostics
Figure 11. Diagnostics Screen
Fault Log
The Fault Log menu will list the truck system initiat-
ing the fault, the error code associated with the fault,
the hourmeter reading when the fault occurred, the
number of times the fault has been logged, and the
system temperature when the fault occurred. See
Figure 12. To scroll through the Fault Log menu, de-
press and HOLD the #1 and the #2 switches. The
system will retain the last 10 faults recorded.
Figure 12. Fault Log Screen
9